Maintenance Messages In Key Operator Mode; Customer Check-Up; Submenu Standards FactoryService/Customer - WMF presto Service Manual

Hide thumbs Also See for presto:
Table of Contents

Advertisement

If activated („yes"), the key operator is able to
• do the descaling (turbo descaling)
• carry out and reset the customer check-up
• exchange and rinse the scale filter
• access the component test
• access the service routines
• access the counters

Maintenance messages in Key Operator mode

Customer check-up

Maintenance after 1 year or 15,000 brewings
Tasks to be performed analogy to customer check-up
3.10
Submenu standards factory
customer
After tapping "self-detect" is first run automatically. All
components operating on 24 V or 30 V are automatically
addressed. The components are automatically identified.
During self-detect the grounds container must be in
place, the adjustable screen closed or the 24/30 V circuits
of the components are interrupted.
Factory
service/customer menu 1
Configuration of grinders is registered automatically (see
chapter portioner).
Configuration of powder portioner is registered
automatically (see chapter portioner).
Heating capacity can be changed as required.
WMF presto Service manual edition 11/2011
if „no" is activated: no access to component test, service routines and
counter.
if „yes" is activated: customer check-up can be performed.
if „yes" is activated: water filter can be exchanged and rinsed.
Configuration of grinders
Configuration of powder portioner
Heating capacity
WMF presto Service Manual
Reset with C on display see
machine data
 
Customer check-up
or Menu Care
service/
check-up
See chapter engineering, portioner
in the training manual
 
service date
 
Customer
9