< WSW18 >
Selector No.
1
Not used.
2
Detection enabled time for CNG
and no tone
3
4
Not used.
5
6
Registration of station ID
7
Tone sound monitoring
8
- Selectors 2 and 3: Detection enabled time for CNG and no tone
After the line is connected via the external telephone or by picking up the handset of the
machine, the machine can detect a CNG signal or no tone for the time length specified by
these selectors. The setting specified by these selectors becomes effective only when
selector 8 on WSW20 is set to "1."
- Selector 6: Registration of station ID
Setting this selector to "0" permits the registration of station ID for Austrian and Czech
models.
- Selectors 7 and 8: Tone sound monitoring
These selectors set monitoring specifications of the tone sound inputted from the line.
Function
No. 2
No. 7
App. 1-23
Setting and Specifications
3
0
0: 40 sec.
0
1: 0 sec. (No detection)
1
0: 5 sec.
1
1: 80 sec.
0: Permitted
1: Prohibited
8
0
0: No monitoring
0
1: No monitoring
1
0: Up to phase B at the calling
station only
1
1: All transmission phases both
at the calling and called
stations