3-3
Control Panel LEDs
The control panel located on the front of the SC116TS-R700WBP chassis has fi ve
LEDs. These LEDs provide you with critical information related to different parts of
the system. This section explains what each LED indicates when illuminated and
any corrective action you may need to take.
Information LED
See the following table for the status shown by this LED.
Status
Continously on and red
Blinking red (1 Hz)
Blinking red (0.25 Hz)
Solid blue
Blinking blue (300 msec)
2
NIC2
Indicates network activity on LAN2 when fl ashing.
1
NIC1
Indicates network activity on LAN1 when fl ashing.
HDD
Indicates IDE channel activity when fl ashing.
Information LED
Description
An overheat ocondition has occured. (This may be caused by cable congestion.)
Fan failure: check for an inoperative fan.
Power failure: check for an inoperative power supply.
Local UID has been activated. Use this function to locate the server in a rack
environment.
Remote UID has been activated. Use this function to locate the server from a
remote location.
3-3
Chapter 3: System Interface