Electrical Specifications

The following electrical specifications apply to the Power Hub component of the Roadster
Orbital Movement System.
Warning: Class I equipment – This equipment must be earthed
Universal Input from 100 – 230 VAC, (50 – 60 Hz)
Rated power: 100 W
Fuse: Power supply output fuse: 2.5 A, 250 V slow blow only.

Environmental Specifications

Maximum ambient temperature (Ta): 40
IP Rating: IP 20

Cable and Connector Specifications

DMX and Modual Link

Cables: Belden 9841 or equivalent (meets specifications for EIA RS-485 applications) with
the following characteristics:
• 4-conductor two twisted pairs plus a shield
• Maximum capacitance between conductors: 30 pF/ft
• Maximum capacitance between conductor and shield: 55 pF/ft
• Maximum resistance: 20 Ohm/100 ft
• Nominal impedance: 100–140 Ohm
Connectors: Two 5-pin male and female XLR connectors:
• Pin 1 Ground
• Pin 2 Data–
• Pin 3 Data+
• Pin 4 Secondary data–
• Pin 5 Secondary data+
Terminator: 5-pin male XLR connector with a 120 Ohm terminating resistor fitted between
pins 2 and 3.

Power Hub to Christie Digital Projector Connection

Cable: DB9 M-F RS-232