2-9. ELECTRICAL
REQUIREMENTS
2-10
The gas fryer requires 120 volt, single phase 60 Hertz, 10
amp, 3 wire grounded (earthed) service, or 230 volt, single phase,
50 Hertz service. The 120 volt gas fryer is factory equipped with a
grounded (earthed) cord and plug for your protection against
shock, and should be plugged into a 3 prong grounded (earthed)
receptacle. Do not cut or remove grounding (earthing) prong. A
wiring diagram is located behind the right side panel, and can be
accessed by removing the side panel. The 230 volt plug must
conform to all local, state, and national codes.
To avoid electrical shock, do not disconnect the ground
(earth) plug. This fryer must be adequately and
safely grounded (earthed). Refer to local electrical
codes for correct grounding (earthing) procedures or in
absence of local codes, with The National Electrical
Code, ANSI/NFPA No. 70-(the current edition). In
Canada, all electrical connections are to be made in
accordance with CSA C22.1, Canadian Electrical Code
Part 1, and/or local codes.
To avoid electrical shock, this appliance must be
equipped with an external circuit breaker which will
disconnect all ungrounded (unearthed) conductors. The
main power switch on this appliance does not disconnect
all line conductors.
Model OFG- 390
703