4-2. ERROR CODES (Continued)
DISPLAY
"E10"
"E15"
"E-20 A"
"E-20 B"
"E-20 C"
"E20 D"
"E20 E"
"E20 F"
"E20 G"
"E20 H"
4-3
CE Only - Along with the error codes from page 4-2, CE
units have the following self-diagnostic error codes:
CAUSE
High limit
Reset the high limit by manually pushing up on the red reset
button; if the high limit does not reset, the high limit must be
replaced
Drain switch
Close the drain, using the drain valve handle; if display still
shows "E-15", have the drain microswitch checked
Air pressure
Press the timer button to try the ignition process again,
switch failure
and if "E-20 A" persists, call Henny Penny's Service
(stuck closed)
Department
Draft fan or
Press the timer button to try the ignition process again,
air pressure
and if "E-20 B" persists, call Henny Penny's Service
switch failure
Department
(stuck open)
Left gas module
Press the timer button to try the ignition process again, and if
failure
"E-20 C" persists, call Henny Penny's Service Department
Right module
Press the timer button to try the ignition process again, and if
failure
"E-20 D", persists, call Henny Penny's Service Department
Both modules
Press the timer button to try the ignition process again, and if
failure
"E-20 E", persists, call Henny Penny's Service Department
Left module
Press the timer button to try the ignition process again, and if
no flame sense
"E-20 F", persists, call Henny Penny's Service Department
Right module
Press the timer button to try the ignition process again, and if
no flame sense
"E-20 G", persists, call Henny Penny's Service Department
Both modules
Press the timer button to try the ignition process again, and if
no flame sense
"E-20 H", persists, call Henny Penny's Service Department
PANEL BOARD CORRECTION