Junction Box Installation

It is recommended to wire the unit from outside
the appliance.
• Remove the junction box assembly located on
the outer shell - right side (see Figure 10.3).
• Cut the zip ties holding the adaptor on the
junction box.
• Remove the junction box from the cover plate.
• Loosen two screws on the Romex connector,
feed the necessary wire through the connector
and tighten the screws.
• Make all necessary wire connections and
reattach the junction box to the cover plate and
to the outer shell.
E. Installing Flame Control Solenoid (Natural Gas Only)
1. Remove the screw and knob from the variable regulator
and discard.
2. Unscrew the nut from the regulator and discard.
3. Remove the bag containing a washer and blue and red
plungers from the side of the flame control solenoid.
Discard the red plunger.
4. Place washer on flame control solenoid (see Figure 10.4).
GAS CONTROL
VALVE
WASHER
FLAME CONTROL
Figure 10.4
30
VARIABLE
REGULATOR
SOLENOID
Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05
Figure 10.3 Junction Box Detail
5. Insert the blue (natural gas) plunger into the flame con-
trol solenoid (see Figure 10.4).
6. Thread the flame control solenoid with correct plunger
into the thread hole in the variable regulator. Turn one to
two turns only. Do not tighten or damage may occur.
7. Connect orange wires from control box to the flame con-
trol solenoid.
NUT
VARIABLE REGULATOR
WASHER
VARIABLE
REGULATOR
PLUNGER
JUNCTION BOX
COVER
PLATE
ROMEX
NOTE: Do NOT wire
110VAC to wall switch.
KNOB
SCREW
SOLENOID
JAM NUT