Heat & Glo Crescent II Owner's Manual
Hide thumbs Also See for Crescent II:
Table of Contents

Advertisement

Quick Links

Model:
Crescent II
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo Crescent II

  • Page 1 See Table of Contents for location of additional Commonwealth appliance is not convertible for use with other of Massachusetts requirements. gases, unless a certifi ed kit is used. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 2: Congratulations

    00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX XXXXXXXX XXXXXXXX (Serie): (Serie): Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 3: Table Of Contents

    B. Facing Requirements ......43 A. Vent Termination Minimum Clearances ....21 Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 4 D. Contact Information ......57  = Contains updated information. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 5: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645G 2/15 Page 1 of 2 Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645G 2/15 Page 2 of 2 Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be pro- tected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 9: User Guide

    Figure 2.1 General Operating Parts protection lockout feature. • Keep remote controls out of reach of children. • Never leave children alone near a hot fi replace, whether operating or cooling down. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 10: Clear Space

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 11: Lighting Instructions (Ipi)

    Keep burner and control compartment clean. See installation and operating instruc- Propane Installation code, CSA B149.1. tions accompanying appliance. For additional information on operating your 593-913i Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 12: After Fireplace Is Lit

    Is it normal to see the pilot fl ame burn turned off. Some optional control systems available with IPI models may allow pilot fl ame to continually? remain lit. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 13: Maintenance And Service

    • Carefully set fi xed glass assembly in place on fi replace. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 14: Maintenance Tasks-Qualifi Ed Service Technician

    Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. • Remove all foreign objects. • Verify unobstructed air circulation. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 15 Cracks tend to close as the appliance heats up. The crack may be repairable with the PATCHKIT-FB. Re- port the case to a Product Specialist with Hearth & Home Technologies. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 16: Installer Guide

    FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.C) OPTIONAL WALL SWITCH MANTEL AND MANTEL LEG (SECTION 5.D & 13.A) SURROUND GAS LINE SECTION 11.C Figure 4.1 Typical System Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 17: Design And Installation Considerations

    Safety glasses Level Reciprocating saw Flat blade screwdriver Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300ºF minimum continuous exposure rating) Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 18: Framing And Clearances

    Due to high temperatures, the appliance should be locat- ed out of traffi c and away from furniture and draperies. Inches 24-5/8 23-1/2 34-7/8 15-1/8 Millimeters Figure 5.1 Appliance Locations Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 19: Constructing The Appliance Chase

    Sides of Front of Opening Opening Opening Opening to Ceiling Floor Flooring Appliance Appliance Appliance (Vent Pipe) (Height) (Depth) (Width) 15-5/8 24-1/2 Inches Figure 5.2 Clearances to Combustibles Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 20: Mantel And Wall Projections

    Figure 5.3 Clearances to mantels or other combustibles above appliance Top View ½ Inch MANTEL Figure 5.4 Clearances to Mantel Legs or Wall Projections (Acceptable on both sides of opening.) Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 21: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 22 2 sides beneath the fl oor. venting system does not meet these requirements. Figure 6.3 Minimum Clearances for Termination • Vinyl protection kits are suggested for use with vinyl siding. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 23: Vent Information And Diagrams

    DVP6 Effective DVP12 Height/Length DVP24 DVP36 DVP48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 Figure 7.2 DVP Pipe Effective Length Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 24: Vent Diagrams

    Installation requirements to replace the fi rst 90º elbow with two 45º elbows: 4 ft min. (1.22 m) 1/4 in. max. (6 mm) 25 ft max. (7.62 m) Figure 7.3 Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 25 7 ft 2.1 m 4 1/2 ft 1.4 m 15 ft 4.6 m = 38 ft (11.6 m) Maximum = 15 ft (4.6 m) Maximum INSTALLED HORIZONTALLY Figure 7.5 Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 26 Max = V . If V = 0, then H Max = 1-1/2 ft (38 mm) ) cannot exceed 15 ft (381 mm) when using appropriate V Figure 7.6 Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 27 1.4 m 15 ft 4.6 m = 38 ft (11.6 m) Max. *No specifi c restrictions on this value EXCEPT cannot exceed 38 ft (11.6 m) Figure 7.7 Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 28: Vent Clearances And Framing

    * Shows center of vent framing hole for top venting. The center of the hole is one (1) inch (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 29: Install The Ceiling Firestop

    Figure 8.3 Installing Ceiling Firestop INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 30: Appliance Preparation

    • Secure the appliance to the framing by using nails or screws through the nailing tabs. • Holes are also provided in appliance bottom to secure appliance to fl oor. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 31: Installing Vent Pipe (Dvp Pipe)

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 32: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 33: Disassemble Vent Sections

    Figure 10.10. • Pull carefully to separate the pieces of pipe. Figure 10.9 Rotate Seams for Disassembly Figure 10.10 Align and Disassemble Vent Sections Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 34: Install Metal Roof Flashing

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.15. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 35: Install Vertical Termination Cap

    • Rest the small leg on the extended heat shield on top Figure 10.14 Figure 10.14 of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be fi eld constructed. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 36: Install Horizontal Termination Cap

    fl ashing kit and HRC caps are available. When penetrating a brick wall, a brick extension kit is available for framing the brick. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 37: Gas Information

    fl exible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 38: Electrical Information

    Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 39: Electrical Service And Repair

    Verify proper operation after servicing. WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 40: Junction Box Installation

    PLATE ROMEX NOTE: Do NOT wire 110- 120 VAC to wall switch. Figure 12.3 Junction Box Detail Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 41: Installing Flame Control Solenoid (Natural Gas Only)

    GAS CONTROL VALVE KNOB SCREW WASHER VARIABLE REGULATOR WASHER VARIABLE REGULATOR SOLENOID FLAME CONTROL SOLENOID VARIABLE JAM NUT REGULATOR PLUNGER Figure 12.4 Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 42: Finishing

    Figure 13.1 Clearances to mantels or other combustibles above appliance Top View ½ Inch MANTEL Figure 13.2 Mantel leg or Wall projections (Acceptable on both sides of opening.) Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 43: Facing Requirements

    To cut the arch use the dimensions shown in Figure 13.6. 30-13/16 IN. Figure 13.3 Outside Fit Surround To cut the arch use the dimensions shown in Figure 13.4. 23-5/8 IN. Figure 13.6 Inside Facing Dimensions Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 44: Appliance Setup

    WARNING! Risk of Fire and Electric Shock! Use ONLY Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 45: Install The Log Assembly

    fi rebox, and tip the log so it rests on the log set. It is recommended using the clear rock which is no burner tube. bigger than one inch. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 46 Note: Do not overspray the clear rock. Overspray will prevent light from shining through. STEP 7: (SRV2083-185) Final placement appearance. 2083-903C Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 47: Fixed Glass Assembly

    NOTICE: If sooting occurs, provide more air by opening the air shutter. AIR SHUTTER SETTINGS Figure 14.2 Glass Assembly CRESCENT-II 1/16 in. FULL OPEN Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 48: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. D. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 2.7. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 49 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 50: Reference Materials

    Ø I GAS LINE ACCESS Location Inches Millimeter Location Inches Millimeter 23-1/4 20-1/8 5-3/16 30-3/4 4-1/2 24-5/16 13-1/2 1-3/4 11-1/4 39-7/8 1013 15-1/8 2-7/8 Figure 16.1 Appliance Dimensions Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 51: Vent Components Diagrams

    14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 52 (305 mm) 79 mm 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 Figure 16.3 DVP vent components Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 53 (184 mm) (98 mm) 12-1/2 in. (318 mm) 5-1/4 in. 10-1/2 in. (133 mm) (267 mm) DVP-TV DVP-TVHW VerticalTermination Cap VerticalTermination Cap (Highwind) Figure 16.4 DVP vent components Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 54 146 to 213 mm 3° 87° 15 in. (381 mm) 10-1/2 in. 267 mm 10-7/8 in. 276 mm DVP-HRC-SS NOT APPROVED FOR ALL UNITS. DVP-HRC-ZC-SS NOT APPROVED FOR ALL UNITS. Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 55: Service Parts

    Control Module 593-592 Circuit Board 2083-030 2083-031 Wall Switch Wire (4 Lead) 593-593A 3V Adaptor Plug 12V Adaptor 2083-022 Junction Box 4021-013 Additonal service parts on following page. 4/15 Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 56: Service Parts

    4041-128 Wire Assembly 593-590A Conversion Kit NG NGK-CRESCENTII Conversion Kit LP LPK-CRESCENTII Pilot Ori ce NG 593-528 593-527 Pilot Ori ce LP Regulator NG NGK-DXV LPK-DXF Regulator LP Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...
  • Page 57: Contact Information

    5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945C Printed in U.S.A. - Copyright 2015 Heat & Glo • Crescent II • 2083-902 Rev. U • 4/15...

Table of Contents