NOTE: 1. Ignition module, valve, pilot, and wall switch operate on
3 volts. 120 VAC is required at junction box unless equipped with
battery back-up.
TO JUNCTION
BOX (110V)
f i r e - p a r t s . c o m
Figure 12.1 IPI Wiring Diagram
D. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
E. Junction Box Installation
If the box is being wired from the INSIDE of the appli-
ance:
• Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to dis-
engage it from the outer shell (see Figure 12.2).
• Pull the electrical wires from outside the appliance through
the opening into the valve compartment and secure wires
with a Romex connector. See Figure 12.2.
• Make all necessary wire connections to the junction
box/receptacle and reattach the junction box/receptacle
to the outer shell.
30
MODULE
FLAME
MODULATION
Heat & Glo • 6000CBV-IP, 8000CBV-IPI • 2167-900 Rev. C • 9/09
FLAME
IGNITER
SENSE
BATTERY PACK
6V DC (AA X 4)
WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
Figure 12.2 Junction Box Detail
RC100
RC200
(OPTIONAL WALL CONTROLS)
THERMOSTAT WIRE
ASSEMBLY / WALL
SWITCH WIRE
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
GRN wire
to GRN screw with
inside box
GRN wire
NOTICE: DO NOT wire
110 VAC to wall switch.