Heat & Glo Crescent II Owner's Manual

Installation and operation
Hide thumbs Also See for Crescent II:
Table of Contents

Advertisement

Quick Links

Model:
Crescent II
Important operating
and maintenance
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing proper-
ty damage, personal injury, or death.
• Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must
be installed in accordance with the manufacturer's instruc-
tions and the manufactured home construction and safety
standard, Title 24 CFR, Part 3280 or Standard for Installa-
tion in Mobile Homes, CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indi-
cated on the rating plate.
CAUTION
DO NOT DISCARD THIS MANUAL
Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot during
operation and cool down.
• Keep children away.
• CAREFULLY SUPERVISE children in same room as
appliance.
• Alert children and adults to hazards of high
temperatures.
• Do NOT operate with protective barriers open or
removed.
• Keep clothing, furniture, draperies and other
combustibles away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fixed glass panel. Do
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fitter;
• a CO detector shall be installed in the room where the
appliance is installed.
Installation and service of this appliance should be
performed by qualified personnel. Hearth & Home
Technologies suggests NFI certified or factory-trained
professionals, or technicians supervised
by an NFI certified professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo Crescent II

  • Page 1 • installation must be performed by a licensed plumber or gas fitter; • a CO detector shall be installed in the room where the appliance is installed. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Owner’s Manual Installation and Operation Leave this manual with party responsible for use and operation.
  • Page 2 0.0 in w.c. (Po. Col. d’eau) IN CANADA Model: 0-0000 FT. 0000-0000FT. (Modele): 00,000 00,000 00,000 00,000 Serial #XXXXX #XXXXX (Serie): Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Model Number MADE IN USA Serial Number XXXXXXXX XXXXXXXX...
  • Page 3: Table Of Contents

    Section 13: Section 14: Section 15: Section 16: = Contains updated information. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Gas Information A. Fuel Conversions ... 25 B. Gas Pressures ... 25 C. Gas Connection ... 25 Electrical Information A.
  • Page 4: Listing And Code Approvals

    Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Maximum Minimum...
  • Page 5: Getting Started

    • Installation and/or use of any component part not approved by Hearth & Home Technologies. Any such action may cause a fire hazard. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 WARNING Inspect appliance and components for damage.
  • Page 6: Framing And Clearances A. Selecting Appliance Location

    • Clearances and Mantel Projections (Section 3.C and 3.D) • Vent Clearances and Framing (Section 6) 24-5/8 23-1/2 Inches Millimeters Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 WARNING Fire Risk Provide adequate clearance: • Around air openings • To combustibles •...
  • Page 7: Constructing The Appliance Chase

    Ceiling (Height) (Depth) (Width) 15-5/8 24-1/2 Using facing material totalling 3/4 inch thick. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Clearances WARNING Fire Risk. Odor Risk. • Install appliance on hard metal or wood surfaces extending full width and depth of appliance.
  • Page 8: Mantel Projections

    HEADER BOARD 7-3/4 IN. 2-3/4 IN. FROM BOTTOM OF HOOD (VISIBLE WITH DOOR REMOVED) 1 in. Note: All measurements in inches. ½ Inch Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 CEILING 27 IN. 13-3/4 IN.
  • Page 9: Termination Locations

    Over 18/12 to 20/12 ... 7.5 Over 20/12 to 21/12 ... 8.0 Figure 4.2 Figure 4.2 specifies minimum vent heights for various pitched roofs. Figure 4.3 Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 HORIZONTAL OVERHANG 2 FT. 20 INCHES VERTICAL MIN.
  • Page 10 Heat & Glo assumes no responsibility for the improper perfor- mance of the appliance when the venting system does not meet these requirements. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 (See Note 2) U.S. (3 FT)
  • Page 11: Vent Information And Diagrams

    (flange of exterior firestop) (see Fig- ure 4.1). 4. Vertical terminations are measured to bottom of termi- nation cap. DVP PIPE elbow. On Figure 5.2 Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 HORIZONTAL Length/ Pipe Inches DVP4 DVP6...
  • Page 12: Vent Diagrams

    1. Top Vent - Horizontal Termination One Elbow Figure 5.3 Two Elbows HORIZONTALLY Figure 5.4 WARNING INSTALLED Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Minimum Maximum Elbow only 2 ft 610 mm 6 in 152 mm...
  • Page 13 4-1/2 ft 1.4 m *When using V Max = V ) cannot exceed 15 ft (381mm) when using appropriate V Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Max. Min. 2 ft 610 mm 2 ft...
  • Page 14 1067 mm 4 1/2 ft 1.4 m *No specific restrictions on this value EXCEPT Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 = 45 ft Max. (13.7m) RESTRICTOR PLATE Note: For vertical venting of 8 feet or higher, the restrictor plate should be used.
  • Page 15 4 1/2 ft 1.4 m 15 ft. 4.6 m = 15 ft (4.6m) Maximum INSTALLED HORIZONTALLY Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Minimum H 3 ft. 7 ft. 17 ft. 5 ft. 7 ft.
  • Page 16: Vent Clearances And Framing

    Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 39-7/8 in. * Shows center of vent framing hole for top venting.
  • Page 17: Vertical Penetration Framing

    Figure 6.3 BEND TABS IN AROUND PIPE ATTIC SHIELD INSTALLED BELOW CEILING Figure 6.4 Installing the Attic Shield Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 ATTIC ABOVE 3 FASTENERS PER SIDE ATTIC SHIELD INSTALLED ABOVE CEILING...
  • Page 18: Appliance Preparation

    • Do NOT notch into the framing around the appliance spacers. Failure to keep insulation, framing or other material away from the appliance may cause fire. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 FRONT VIEW...
  • Page 19: Installing Vent Pipe

    Figure 8.1 Figure 8.2 Note: Make sure that the seams are not aligned to prevent unintentional disconnection. CORRECT Figure 8.4 Seams Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Lances Figure 8.3 INCORRECT...
  • Page 20 If the slip section is too long, the inner and outer flues of the slip section can be cut to the desired length. Figure 8.5 Figure 8.6 Slip Section Pilot Holes Figure 8.7 Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Screws into Slip Section...
  • Page 21: Disassembly Of Vent Sections

    Improper support may allow vent to sag or separate. Figure 8.8 Securing Vertical Pipe Sections Figure 8.9 Securing Horizontal Pipe Sections Figure 8.10 Figure 8.11 Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Rotate Seams for Disassembly Align and Disassemble Vent Sections...
  • Page 22: Installing Heat Shield And Horizontal Termination Cap

    NOTE: Where required, an exterior wall flashing is available. When penetrating a brick wall, a brick extension kit is available for framing the brick. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 WARNING Burn Risk • Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap.
  • Page 23: Installing Roof Flashing And Vertical Termination Cap

    (see Figure 8.14). OVERHANG VERTICAL WALL ROOF PITCH IS X/ 12 (1 of 3) H (Min.) Ft. CAULK Figure 8.14 Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 TERMINATION CAP STORM COLLAR SCREWS Termination Cap - DVP-TVHW...
  • Page 24 Caulk around the top of the storm collar (see Figure 8.14). Figure 8.15 Assembling the Storm Collar Figure 8.16 Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Assembling the Storm Collar Around the Pipe...
  • Page 25: Gas Information

    2-1/2 inches in diameter and does not penetrate the firebox. Propane 11.0 inches w.c. 14.0 inches w.c. 10.0 inches w.c. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 WARNING Gas Leak Risk • Support control when attaching pipe to prevent bending gas line.
  • Page 26 To identify the proper orifice size, check with the local gas utility. If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05...
  • Page 27: Electrical Information

    (Figure 10.2). Label all wires prior to disconnection when servicing con- trols. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 CAUTION WARNING Shock hazard.
  • Page 28 50-025302-D *Note: Appliance will not operate unless properly grounded. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05...
  • Page 29 Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 50-025302-D...
  • Page 30: Junction Box Installation

    7. Connect orange wires from control box to the flame con- trol solenoid. VARIABLE REGULATOR VARIABLE VARIABLE REGULATOR Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 JUNCTION BOX COVER PLATE ROMEX NOTE: Do NOT wire 110VAC to wall switch.
  • Page 31: Finishing

    (VISIBLE WITH DOOR REMOVED) 1 in. ½ Inch To cut the arch use the dimensions shown in Figure 11.4. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 CAUTION For Outside Fit Surrounds • Surface temperatures are hot around fireplace opening.
  • Page 32 (see Figure 11.5). Figure 11.5 Inside Fit Surround To cut the arch use the dimensions shown in Figure 11.6. 30-13/16 IN. 23-5/8 IN. Figure 11.6 Inside Facing Dimensions Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05...
  • Page 33: Appliance Setup

    See Service Parts List for appropriate ac- cessories. Refer to Section 16. SHIPPING BRACKET Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 WARNING Shock or fire risk. Use ONLY optional accessories approved for this appliance.
  • Page 34: Positioning The Logs

    STEP 4: Place clear rock on top of orange film in front of log set. It is recommended using the clear rock which is no bigger than one inch. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 BURNER SCREWS...
  • Page 35 STEP 6: Turn on ember light/ember bed. Use high temperature black paint and lightly fog the clear rock. Note: Do not overspray the clear rock. Overspray will prevent light from shining through. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05...
  • Page 36: Glass Assembly

    • Reinstall the glass, orange film, burner and logs, lava and clear rocks. For placement of logs and rock refer to the log placement instructions in Section 12-D. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 CAUTION BURNER SCREWS (2)
  • Page 37: Operating Instructions

    Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 WARNING HOT! DO NOT TOUCH.
  • Page 38: Lighting Appliance

    Bedroom or a Bedsitting Room. For assistance or additional informa- tion, consult a qualified installer, ser- vice agency or the gas supplier. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 LIGHTING INSTRUCTIONS (IPI) 1. Turn off all electric power to the appli- ance.
  • Page 39: After Appliance Is Lit

    In an Intellifire ignition system it is normal to see the pilot flame, but it should turn off when ON/OFF is turned off. In a standing pilot system the pilot will always stay on. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 CAUTION CAUTION •...
  • Page 40: Troubleshooting

    The sensor rod may be contaminated. Clean sensor rod with emery cloth. Verify that module is securely grounded to metal chassis of appliance. Verify that wire harness is firmly connected to module. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05...
  • Page 41 14 in. W.C. Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in. Verify module is securely grounded to metal chassis of appliance. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05...
  • Page 42: Maintaining And Servicing Appliance

    Refer to maintenance instructions. • Combustible materials blocking cap may ignite. • Restricted air flow affects burner operation. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 CAUTION Handle glass assembly with care. NOTE: Clean glass after initial 3-4 hours operation.
  • Page 43 6. Inspect draft shield to verify it is not bent, damaged or missing. Remote controls 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. Maintenance Tasks Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Recommend addition of screen...
  • Page 44: Reference Materials

    Appliance Dimensions Table Location Figure 16. 1 Appliance Dimensions Inches Millimeter Location 23-1/4 20-1/8 30-3/4 24-5/16 1-3/4 15-1/8 Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Ø I Inches Millimeter 5-3/16 4-1/2 13-1/2 11-1/4 39-7/8 1013 2-7/8 ELECTRICAL...
  • Page 45: Vent Components Diagrams

    45 ° 1 in. 14 in. DVP-WS (Wall Shield) 10 in. 1-1/2 in. 24 in. 12 in. DVP-AS (Attic Shield) Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Pipe Length/Inches DVP4 DVP6 DVP12 DVP24 DVP36 DVP48...
  • Page 46 Effective 8 in. DVP-TRAP SERIES Horizontal Term Cap DVP-TRAP1 DVP90ST DVP-TRAP2 Wall Shield Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 Length Minimum Maximum Term Cap Effective Length Effective Length TRAP1 4-1/8 in. 5-5/8 in. TRAP2 6-3/4 in.
  • Page 47 DVP Components 13-7/8 in. 9-1/2 in. 11-5/8 in. 12-1/8 in. 14 in. 7-1/8 in. 5-3/4 in. DRC-RADIUS COOL-ADD Cap Shield Cap Shield Figure 16. 4 DVP vent components Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05...
  • Page 48: Service Parts

    C. Service Parts List CRESCENT II (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 4-05 Ending Manufacturing Date: ______ Log Set Assembly with burner Part number list on following page. Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05...
  • Page 49 Remote Control Kit Remote Control Kit Note: Replacement bulbs to be supplied by homeowner. Recommended replacement: Sylvania mini candelabra 75 watts. DESCRIPTION Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 CRESCENT II SERIAL # PART NUMBER...
  • Page 50: Warranty

    Product. HEAT & GLO also reserves the right to discontinue styles and products. © 2005 Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 060-981C 1/05...
  • Page 51: Contact Information

    Read, understand and follow these instructions for safe installation and operation. Printed in U.S.A. - Copyright 2005 Heat & Glo • Crescent II • 2083-902 Rev. G • 9/05 • Leave this manual with party responsible for use and operation.

Table of Contents