Command Summary - Siemens Advance Network Gateway User Manual

Gateway with ethernet
Hide thumbs Also See for Advance Network Gateway:
Table of Contents

Advertisement

Command Summary

Description
add
config
del
display
2000590-001
This section summarizes the command syntax for the Advance Network
Gateway (ANG_EN) software.
Adds an ADH Unit to the Address Translation Table
format: add adh loop unit
Where loop is a number in the range 1- 8.
Where unit is a number in the range 1-31.
This command permits configuration of the ANG_EN
format: config display
format: config time server ip xxx.xxx.xxx.xxx
Where xxx.xxx.xxx.xxx is the IP address of the time server
format: config address ip xxx.xxx.xxx.xxx
Where xxx.xxx.xxx.xxx is the IP address.
format: config address ethernet xx.xx.xx.xx.xx.xx
Where xx.xx.xx.xx.xx.xx is the Ethernet address.
format: config loop x
Where x is a number in the range 1-8.
format: config unit x
Where x is a number in the range 1-31.
format: config iproute xxx.xxx.xxx.xxx
Where xxx.xxx.xxx.xxx is the IP address.
format: config netmask xxx.xxx.xxx.xxx
Where xxx.xxx.xxx.xxx is the IP address.
Deletes the specified ADH Unit from the Address Translation Table
format: del all
format: del adh loop unit
Where loop is a number in the range 1- 8.
Where unit is a number in the range 1-31.
format: del ip xxx.xxx.xxx.xxx
Where xxx.xxx.xxx.xxx is the IP address.
Generates display of the specified ADH Unit(s) from the ATT
format: display all
format: display adh loop unit
Where loop is a number in the range 1-8.
Where unit is a number in the range 1-31.
loop & unit are optional parameters
no options defaults to this ANG_EN loop
loop only displays all Units in specified loop
loop unit displays specified ADH unit
format: display ip xxx.xxx.xxx.xxx
Where xxx.xxx.xxx.xxx is the optional IP address.
no option defaults to this ANG_EN IP
Data Communications Setup
45

Advertisement

Table of Contents
loading

Table of Contents