DOOR OPEN

No signal from the "Door closed" during
programme operation. If the input signal for
"Door closed" is lost during programme
operation, the OPEN DOOR error code is
immediately generated.
If the power is on, be very careful when
working on the the machine.
1. Try to restart the machine (i.e. reset the error code)
by pressing START.
Error message returns
2. Exit the programme using a. Enter the service
Fig.
programme (unlock the door if it is locked). Verify
8
voltage supply is present between X5:4 - 5 when the
door is closed.
No voltage
Fig.
9
3. Verify voltage is present between X5:3 - 5.
Voltage present
Continued on next page
438 9152-11/03
04.03
12. Troubleshooting
No error message
Temporary error (probably
defective contact)
Voltage present but black
square does not light
I/O card 1 A11 probably
defective.
No voltage
Troubleshoot the cabling for
the voltage supply (between
the main power switch Q1
and X6).
8
X5
X6
9
SERVICE PROGRAM
LEVEL
2
TEMP
22°C
SPEED
0
DRAIN CLOSED
YES
EMERGENCY STOP
DOOR LOCKED
TEMPORARY PAUSE
DOOR CLOSED
OIL
REMOTE START
IMBALANCE
SERVICE
PHASE CHECK
Indication Door locked
12
3973
5390
15