23
• I/O cards A11 and A12
Most smaller machines have only one card: A11. On some machines,
there is a greater need for outputs, in which case two I/O cards are
used.
The I/O cards are controlled by the CPU card via a serial interface. The
I/O cards feature outputs, which, via the communication cards in the rear
electric box, control various machine functions, such as the water
valves, heater connection and drain valve. On the input connection
blocks of the communication cards, it is possible to connect signals for
control of e.g. the detergent supply.
The cards also have inputs for emergency stop and door lock ACK.
2
Temp.
Door lock controller
A31
Level
guard B2
Heater
elements
K21
Voltage
supply
4
23. Programme unit
Programme unit
Level guard
Motor
Door lock
controller
A41
U1
Emergency
M1
Display card
A1
Card reader
I/O card 1
A11
Transformer
T10
stop
Service
Manual
Control panel
I/O card 2
A12
Communication card A22
Communication card
A21
Drain
Water
valves
valves
5370
438 9145-41/03