Electrolux W365H Service Manual page 186

Clarus control
Hide thumbs Also See for W365H:
Table of Contents

Advertisement

29
Fig.
X95: Input from rotation sensor on motor
22
shaft
Fig.
When the motor is operating, a pulse train is
23
applied on the input.
Input
Function
Pin 1:
0 V
Pin 2:
Tacho signal
X96: Output to door lock
Locks the door lock when the following conditions
are met:
• DC 200-240 V on input X92 (programme unit
request door locking)
• DC 0 V on input X93 (no water in drum)
• DC +5 V on input X94 (motor not activated)
• <3 Hz on input X95 (drum not rotating)
• No error code present
Unlocks the door lock when the following
conditions are met:
• DC 0 V on input X92 (programme unit request
door opening)
• DC 0 V on input X93 (no water in drum)
• DC +5 V on input X94 (motor not activated)
• <3 Hz on input X95 (drum not rotating)
• No error code present
Voltage
DC 17-31 V, + on pin 1, - on pin 2
DC 17-31 V, - on pin 1, + on pin 2
18
29. Door and door lock
Function
Unlock the door
Locks the door
22
Door lock control A31
Tacho generator
B3
X95
1
2
Unlocks +
Locks
Y80
Door lock A41
23
Service
Manual
-
-
+
1
2
X96
5933
5928
438 9145-61/06