Electrolux W365H Service Manual page 125

Clarus control
Hide thumbs Also See for W365H:
Table of Contents

Advertisement

Service
Manual
BUZZER ON BUTTON
MAX FILLING TIME
MAX HEATING TIME
SHOW WEIGHT TIMEOUT
PC5 BLOCKING OF HEATING
PC5 BLOCKING OF SPINNING
HEAT 2 AS STANDARD
SERVICE ALARM HOURS
BUZZER TIMEOUT AT END
BUZZER TIMEOUT AT PAUS
ERROR, OVERFILLED
PASSWORD ACTIVE
CMIS ADDRESS
LEVEL IN MM ACTIVE
START SLOW FILLING, HG
OFFSET LEVEL, HG
READY
Y/N
SERVICE ALARM HOURS
1
4
7
438 9145-41/03
03.11
23. Programme unit
Y
10:00
10:00
0:20
N
Y
Y
Y
Y
Y
Y
Y
0
Y
10
2
Answer Yes (Y) or No (N).
Press
.
0
Use the numeric keys to
2
3
enter the value.
5
6
8
9
If you make a mistake while
entering digits:
0
Press ERASE.
When you have finished:
Press
.
Relay for steam as standard
Here you decide if the machine should heat with
steam or el. Yes (Y) the machine will heat with
steam (standard) and No (N) the machine will heat
with el.
Service interval
Here you determine the interval between service
interventions on the machine.
The statistics function of the programme unit
contains a counter that can be reset to show the
number of hours of effective washing on the
machine since the last service intervention.
STATISTICS
TOTAL RUN TIME HOURS
HOURS SINCE LAST SERVICE
LAST 5 ERROR CODES
PROGRAM
08 NO HEAT
08 NO HEAT
08 NO HEAT
08 NO HEAT
08 NO HEAT
When the service technician has serviced the
machine, this counter is reset.
When the time on the counter exceeds the
programmed interval, "S" is displayed in the lower,
left corner of the display indicating the need for
Service.
991 NORMAL 95°C
PROGRAM STEP: MAIN WASH
STEP TIME:
SET TEMPERATURE:
ACTUAL TEMPERATURE:
REMAINING TIME:
DRUM SPEED:
RAPID ADVANCE
PAUSE
S
23
0
0
0
HOURS
991
0
996
0
993
0
991
0
991
0
READY
1
720 SEC
85 °C
21 °C
70 MIN
48 RPM
SELECT
39

Hide quick links:

Advertisement

Table of Contents
loading