30

Function

Be careful when measuring the electric components in the motor
control. All components have a potential difference of approx. 300 V
in relation to protective earth and neutral.
When the green LED on the motor control card is lit, the compo-
nents carry dangerous voltages.
The motor control lose all voltage about 10-30 seconds after the
voltage has been disconnected and the motor has stopped.
The.motor.control.communicates.with.the.programme.unit.via.a.serial.two-
Fig.
way.interface..With.the.help.of.the.motor.control,.the.programme.unit.can.
3
control.not.only.the.instantaneous.motor.rpm,.but.also.with.high.precision.
the.acceleration.and.retardation.of.the.motor.in.order.to.reach.the.target.
rpm..The.motor.control.continuously.replies.with.information.to.the.pro-
gramme.unit.PCB.regarding.the.current.operating.state.and.sends.reports.
if.an.error.occurs.
3
Program-
me.unit.
X301
Imbalance.switch.
6
30. Motor and motor control
DANGER
Voltage.supply.
X311
Motor.control
X308
Door.lock.
connector
X304
X312
X312
X302
Door.lock.switch
Service
Manual
Feed.
Motor
Thermal.protection.
230.V
438 9145-81/07