Electrolux W365H Service Manual page 92

Clarus control
Hide thumbs Also See for W365H:
Table of Contents

Advertisement

23
3
P1, P2 Used for factory
calibration of the
pressure sensor.
Pressure
sensor
Green LED:
Quick blinks = communication
between CPU card and I/O card.
6
23. Programme unit
The two pins in switch X7 are shorted to confirm
changes made in Configuration 1 and 2.
(Not for FOM71 CLS).
Pushbutton SW1: used as an
acknowledgement button when in the
Service programme mode (the same
function is also available on the
communication card).
X1
X2
X3
X4
2
1
3
2
1
3
2
1
4
3
Card Switch Function
X1
Input from water temperature sensor
X2
not used
X3
not used
X4
Output to motor controller
X5: 1-3
Serial communication with I/O card 1
X5: 4-5
Voltage supply from I/O card 1
X6: 1-5
Serial communication with display card
X6: 6-7
Voltage supply to display card
X7
PC communication
X8
Motor communication (reserved)
X9
Scale communication
X10
Internal communication (not used)
X5
X6
2 1
5 4
3
2
1 7
6
5
4
Service
Manual
3 2
1
X7
X8
X9
X10
Red LED:
Continuous red light = voltage
supply OK
438 9145-41/03
X7
3972
03.11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents