Electrolux W365H Service Manual page 177

Clarus control
Hide thumbs Also See for W365H:
Table of Contents

Advertisement

Service
Manual
Fig.
X95: Input from rotation sensor on motor
10
shaft
Fig.
When the motor is operating, a pulse train is
11
applied on the input.
Input
Function
Pin 1:
DC 4-10 V feed
Pin 2:
0V
Pin 3:
DC 4-10 V pulse input
Frequency > 0.4 Hz: drum is rotating
Frequency < 0.4 Hz: drum is not rotating
X96: Output to door lock
Locks the door lock when the following conditions
are met:
• DC 200-240 V on input X92 (programme unit
request door locking)
• DC 0 V on input X93 (no water in drum)
• DC +5 V on input X94 (motor not activated)
• <0.4 Hz on input X95 (drum not rotating)
• No error code present
Unlocks the door lock when the following
conditions are met:
• DC 0 V on input X92 (programme unit request
door opening)
• DC 0 V on input X93 (no water in drum)
• DC +5 V on input X94 (motor not activated)
• <0.4 Hz on input X95 (drum not rotating)
• No error code present
Voltage
DC 17-31 V, + on pin 1, - on pin 2
DC 17-31 V, - on pin 1, + on pin 2
438 9145-61/06
04.10
29. Door and door lock
Function
Unlock the door
Locks the door
10
Door lock control A31
Rotation sensor
B3
X95
1
2
3
Unlocks +
Locks
Door lock A41
11
29
-
-
+
1
2
X96
Y80
5194
5184
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents