E41: Door Open - Electrolux EWM1100 Service Manual

Front-loading washing machine
Table of Contents

Advertisement

E41
Tests to be performed:
Is the door correctly closed?
To check the wiring (with the door
open), measure the following
wiring connectors:
-between wires J1-3 and J1-1, the
circuit must NOT be open
(measure the resistive value of the
PTC).
- between wires J1-3 and J1-2, the
circuit must be OPEN.
YES
Is the door locking device securely
anchored to the latch?
YES
Replace the door locking device.
Does the appliance function
correctly?
YES
Restart the diagnostic cycle to
check for further alarm conditions.
2007-10 SOI/DT-mdm FCPD-dp Quality-fz

E41: Door open

Maximum time exceeded (PTC = 15 seconds)
YES
NO
NO
NO
NO
Close the door correctly and restart the
diagnostic cycle to check for further alarm
Detach the connectors and
effect measurement on the
component
(fig. 9):
- across connectors 3 and 5
the circuit must not be open
(the resistive value should
be measurable).
- across connectors 4 and 5,
the circuit must be open (the
numbers are printed on the
component).
Is the door safety interlock
is OK?
YES
Check/replace the wiring and
restart the diagnostic cycle to
check for further alarm
conditions.
Replace the door latch or the
door.
Replace the circuit board and
restart the diagnostic cycle to
check for further alarm
conditions.
30/59
E41
conditions.
Replace the door
interlock and
restart the
NO
diagnostic cycle
to check for
further alarm
conditions.
599 70 32-47