Service
Manual

Reset button

The door lock control features a reset button
Fig.
used to reset the programme routines stored in
5
the computer. When pressed, any error codes
are erased;
Door lock control inputs/outputs
X90: AC 200-240 V feed
Fig.
6
X91: Transfer of voltage supply
Fig.
Feeds the voltage to programme unit A1.
7
X92: Input from programme unit (via I/O card
1): Lock door
Prior to the door lock controller locking the door
(output X96), a check is made of any water left in
the drum (input X96 closed) and whether the
drum is not
rotating
Input voltage
200-240 V DC:
0 V:
438 9145-61/06
04.10
29. Door and door lock
(
input X94 open).
Function
Programme unit requests door locking
Programme unit requests door
opening
6
Door lock control A31
X90
1
200-
2
240 V
X91
1
Voltage
2
supply to A1
Level guard
B2
X93
1
2
1
X94
Rotation
2
sensor B3
X95
X304
1
2
3
Motor control U1
7
29
2
1
X92
X4
2
1
I/O card 1 A11
5193 B
5184