Electrolux W365H Service Manual page 84

Clarus control
Hide thumbs Also See for W365H:
Table of Contents

Advertisement

21
Communication card A21
Fig.
This card is used to send and receive signals
8
from I/O card 1. It contains:
• Fuses F11 and F12 (T 1.25 A)
Fig.
Protects the received voltage supply in the
9
timer and door lock controller.
• Service button S40
Used to engage service mode of the
programme unit.
• Input/output connection blocks
Card No.
Function
Outputs (200 - 240 V AC)
X71
:1,2
Signal "Door locked, program on"
X72
:2
Liquid detergent 1
:3
Liquid detergent 2
:4
Liquid detergent 3
:5
Liquid detergent 4
:1
0 V
X73
:1
Powder 1 (Y11)
:2
Powder 2 (Y12)
:3
Powder 3 (Y13)
:4
Powder 4 (Y14)
:5
Powder 2 (Y22)
Input
X70
:1,2
Start/Stop
:3,4
Pause/PC5
8
21. Control unit
X40
X41
X42
X43
X44
X45
X46
8
Communication card A21
9
S40
X81
X80
1
1
X70
1
X71
1
1
1
1
X72
X73
1
1
F12 F11
1
1
1
1
X47
X48
Service
Manual
5239
Y11
Y12
Y13
Y14
X53
Y24
Y22
Y15
Y25
X51
Pump
X50
Drain
1
X49
5233
438 9145-21/03