MMB Messages
The power saving is stopped and power is normal.
Corrective action:
No action is necessary.
Severity:
Info
CC6F02FF
Power Saving Started
Meaning:
The power consumption of device exceeded the threshold set up by power saving management in MMB
Web-UI.
Corrective action:
Check the device status.
Please prevent the rising of the load of device in order to limit power consumption.
If this situation continues, the action which set in Power Management Setup menu of MMB Web-UI is
executed.
Severity:
Warning
2.2

List of SVAS message IDs

This section lists the messages related to the SVAS.
SVAS outputs the log to SEL of MMB in the following either event ID detecting the message of the device
driver.
- BC507000
- BC508000
- BC509000
- BC547000
- BC548000
- BC549000
Message ID is included in the output log, and the action is executed according to the following message ID
list. Please confirm details of the message that the device driver output by the event log of OS.

2.2.1 Linux related

■LAN (Linux) related
11001
Adapter error (should not be a VF)
Meaning:
An invalid VF device ID was set for PCIe SR-IOV capability.
Corrective action:
An adapter failure may have occurred. Replace the adapter.
Severity:
Warning
11601
Adapter error (The NVM Checksum Is Not Valid)
Meaning:
An NVM checksum error was detected.
Corrective action:
An adapter failure may have occurred. Replace the adapter.
Severity:
Warning
11602
Adapter error (Hardware Error)
76
C122-E178-02EN