Fujitsu PRIMEQUEST 2000 Series Message Reference page 154

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
Download SEL and contact your sales representative or a field engineer.
Unable to onlining the DR target BMC
Meaning:
Online of the specified SB is failed.
Corrective action:
Download SEL and contact your sales representative or a field engineer.
Unknown Error Code =0xXX
Meaning:
DR process is failed with unknown Error Code.
Corrective action:
Download SEL and contact your sales representative or a field engineer.
BIOS Error Code =0xXX
Meaning:
DR process is failed with BIOS Error Code.
Corrective action:
-
Case 1: Partition is operating and SEL is logged.
(action) Please process it according to SEL.
-
Case 2: Partition is operating and SEL is not logged.
(action) 1. Download SEL and contact your sales representative or a field engineer.
2. Please turn off the power of specified partition and turn on it again.
3. Please process it according to SEL if power off/on of the partition is failed.
Please use it continuously if power off/on of the partition is success
-
Case 3: Partition is reset.
(action) 1. Download SEL and contact your sales representative or a field engineer.
2. Please process it according to SEL if reset of the partition is failed.
Please use it continuously if reset of the partition is success
The specified SB#$ is home SB.
Meaning:
The specified SB cannot remove because it is Home SB in the partition.
Corrective action:
Please confirm configuration of partition.
The specified [SB#$|IOU#$] is not in specified Partition.
Meaning:
The specified SB cannot remove because it is not constituent of the partition.
Corrective action:
Please confirm configuration of partition.
Hot-remove {SB#k|IOU#k} failed.
Meaning:
Hot-remove SB/IOU was failed because an error occurred.
Corrective action:
Please process it according to other message.
Failed to execute DR operation. Configuration is unrecovered.
Meaning:
DR operation was failed and the configuration of hardware is unrecovered. Partition can operate, but DR
function cannot use until the power of the partition is turned off and turned on again.
Corrective action:
Please deal with it according to SEL and syslog of OS.
Please turn off the power of specified partition and turn on it again.
The specified [SB#$|IOU#$] is free.
138
C122-E178-02EN

Hide quick links: