The specified [SB#x|IOU#x] is not present
Meaning:
The specified SB/IOU is not present in system.
Corrective action:
Please confirm SB/IOU number and configuration of the partition. Mount SB/IOU in the slot of the specified
SB/IOU number.
The specified Partition#Z is no Home
Meaning:
The obtaining information of Home SB of the specified partition is failed.
Corrective action:
Please try again. If it fails, contact your sales representative or a field engineer.
Unable to hot-add SB due to SB revision mismatch
Meaning:
Hot-add SB cannot execute because the version of specified SB is invalid.
Corrective action:
Please confirm SB number. Exchange the specified SB if the version of specified SB is different from the
version of SB in the specified partition.
DR sequence timeout: added SB power on failure
Meaning:
Timeout of DR sequence occurred because power of added SB cannot turn on.
Corrective action:
Confirm SEL. Exchange the failure component if a component is failure.
DR sequence timeout: SB hot-add OS failure
Meaning:
Timeout of DR sequence occurred in OS processing.
Corrective action:
Please deal with it according to SEL and syslog of OS.
DR sequence timeout: SB hot-add request failure
Meaning:
Timeout of DR sequence occurred in adding of SB.
Corrective action:
Confirm SEL. Exchange the failure component if a component is failure.
DR sequence timeout: QPI connection failure
Meaning:
Timeout of DR sequence occurred in connecting QPI.
Corrective action:
Please execute the following.
1.
Download SEL and contact your sales representative or a field engineer.
2.
Please process it according to SEL if reset of the partition is failed. Please use it continuously if reset of
the partition is success
Unable to power on the IOU
Meaning:
Power On of the IOU is failed.
Corrective action:
Download SEL and contact your sales representative or a field engineer.
Unable to power on the PCI_Box
Meaning:
Power On of the PCI_Box is failed.
Corrective action: