MMB Messages
Error
BC504130
PCI: ECRC Error Bus: $$ Device: 0x$$ Function: 0x$$
Meaning:
An error was detected in the PCI express packet.
Corrective action:
Referring the Source and Unit of the MMB system event log, replace the unit according Replacement
Component Type A in the
Severity:
Error
BC504140
PCI: Unsupported Request Bus: $$Device: 0x$$Function: 0x$$
Meaning:
An error was detected in the PCI express packet.
Corrective action:
Referring the Source and Unit of the MMB system event log, replace the unit according Replacement
Component Type A in the
Severity:
Error
BC504150
PCI: ACS Violation Bus: $$ Device: 0x$$ Function: 0x$$
Meaning:
An error was detected in the PCI express packet.
Corrective action:
Referring the Source and Unit of the MMB system event log, replace the unit according Replacement
Component Type A in the
Severity:
Error
BC504160
PCI: Uncorrectable Internal Error Bus: $$ Device: 0x$$ Function: 0x$$
Meaning:
An internal error was detected in the PCI express Device.
Corrective action:
Referring the Source and Unit of the MMB system event log, replace the unit according Replacement
Component Type A in the
Severity:
Error
BC504170
PCI: MC Blocked TLP Bus: $$ Device: 0x$$ Function: 0x$$
Meaning:
An error was detected in the PCI express packet.
Corrective action:
Referring the Source and Unit of the MMB system event log, replace the unit according Replacement
Component Type A in the
Severity:
Error
BC504180
PCI: AtomicOp Egress Blocked Bus: $$ Device: 0x$$ Function: 0x$$
Meaning:
An error was detected in the PCI express packet.
Corrective action:
Referring the Source and Unit of the MMB system event log, replace the unit according Replacement
Component Type A in the
'Appendix A Replacement component list
'Appendix A Replacement component list
'Appendix A Replacement component list
'Appendix A Replacement component list
'Appendix A Replacement component list
'Appendix A Replacement component list
'.
'.
'.
'.
'.
'.