Fujitsu PRIMEQUEST 2000 Series Message Reference page 45

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
A temperature rise (Warning) was detected.
Corrective action:
If the Inlet Temp is normal and CPU Temp is abnormal, please check the state of the filter, the heat sink and
installation environment.
Severity:
Warning
B0010591
'CPU#0 Temp': Temperature high critical: $$ C
Meaning:
A temperature rise (Critical) was detected.
Corrective action:
If the Inlet Temp is normal and CPU Temp is abnormal, please check the state of the filter, the heat sink and
installation environment.
When the improvement is not seen, replace the CPU.
Severity:
Error
B0010592
'CPU#1 Temp': Temperature high critical: $$ C
Meaning:
A temperature rise (Critical) was detected.
Corrective action:
If the Inlet Temp is normal and CPU Temp is abnormal, please check the state of the filter, the heat sink and
installation environment.
When the improvement is not seen, replace the CPU.
Severity:
Error
B0018571
'CPU#0 Temp': Temperature OK
Meaning:
The temperature is now normal.
Corrective action:
No action is necessary.
Severity:
Info
B0018572
'CPU#1 Temp': Temperature OK
Meaning:
The temperature is now normal.
Corrective action:
No action is necessary.
Severity:
Info
B0018591
'CPU#0 Temp': Temperature high warning: $$ C
Meaning:
A temperature rise (Warning) was detected.
Corrective action:
If the Inlet Temp is normal and CPU Temp is abnormal, please check the state of the filter, the heat sink and
installation environment.
Severity:
Warning
B0018592
'CPU#1 Temp': Temperature high warning: $$ C
C122-E178-02EN
29