Fujitsu PRIMEQUEST 2000 Series Message Reference page 113

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
Corrective action:
Replace the target device. If the error keeps recurring, contact your sales representative or a field engineer.
Severity:
Warning
■PCIe-SSD (Linux) related
13900
Adapter error(SMP Firmware not in Run mode)
Meaning:
The SMP Firmware was not in Run mode during driver loading.
Corrective action:
Collect the data for investigation (dump or fjsnap). Ask your sales representative or a field engineer to
perform an investigation.
Severity:
Warning
13901
Adapter error(failed to load midprom data)
Meaning:
Loading of midprom information occurred during driver loading.
Corrective action:
Collect the data for investigation (dump or fjsnap). Ask your sales representative or a field engineer to
perform an investigation.
Severity:
Warning
13902
Adapter error(dual plane mode failed)
Meaning:
The setting of Nand Flash to Dual Plane mode failed during driver loading.
Corrective action:
Collect the data for investigation (dump or fjsnap). Ask your sales representative or a field engineer to
perform an investigation.
Severity:
Warning
13903
Adapter error(hardware failure)
Meaning:
An error occurred during driver loading.
Corrective action:
Collect the data for investigation (dump or fjsnap). Ask your sales representative or a field engineer to
perform an investigation.
Severity:
Warning
13904
Adapter error(Entering reduced-write mode)
Meaning:
The adapter entered reduced-write mode.
Corrective action:
Replace the adapter.
Severity:
Warning
13905
Adapter error(Entering read-only mode)
C122-E178-02EN