MMB Messages
Corrective action:
Confirm the connection of the power supply cable.
Severity:
Warning
C9A10F62
Power supply #n turned off (PCIBox or IOU #n-Slot#n-Port#n, Cascade #)
Meaning:
Power supply is turned off.
Corrective action:
Confirm the state of enclosure.
Severity:
Warning
C9A10F7X
Redundant power supply #n failed (PCIBox#n-Slot#n-Port#n, Cascade #)
Meaning:
The PSU broke down.
X is the broke down PSU number.
Corrective action:
Exchange the broke down PSU.
Severity:
Warning
C9A10F80
Power supply redundancy lost (PCIBox#n-Slot#n-Port#n,Cascade #)
Meaning:
The PSU broke down and the PSU redundancy was lost.
Corrective action:
Exchange the broke down PSU.
Severity:
Warning
C9A10F90
EMM #n failed (PCIBox or IOU #n-Slot#n-Port#n, Cascade #)
Meaning:
Problem of enclosure management module is detected.
Corrective action:
Please gather the survey material because a detailed investigation is necessary for that and contact the
repair chat channel.
Severity:
Warning
C9A10F91
EMM #n removed (PCIBox or IOU #n-Slot#n-Port#n, Cascade #)
Meaning:
Enclosure management module is removed.
Corrective action:
1. Please power off the device and confirm status of HDD, SAS cable and power supply.
2. If the problem persists, replace the backplane, expander module and data cable.
Severity:
Warning
C9A10F92
EMM #n Enclosure firmware mismatch (PCIBox or IOU #n-Slot#n-Port#n, Cascade #)
Meaning:
Firmware version of enclosure management module is mismatch.
Corrective action: