Configuring Snmp - ZyXEL Communications MES-3528 User Manual

Layer 2+ metro ethernet switch
Hide thumbs Also See for MES-3528:
Table of Contents

Advertisement

Chapter 33 Access Control

33.3.4 Configuring SNMP

Click Management > Access Control > SNMP to view the screen as shown. Use
this screen to configure your SNMP settings.
Figure 159 Management > Access Control > SNMP
The following table describes the labels in this screen.
Table 102 Management > Access Control > SNMP
LABEL
General Setting
Version
Get Community
292
DESCRIPTION
Use this section to specify the SNMP version and community (password)
values.
Select the SNMP version for the Switch. The SNMP version on the Switch
must match the version on the SNMP manager. Choose SNMP version 2c
(v2c), SNMP version 3 (v3) or both (v3v2c).
Note: SNMP version 2c is backwards compatible with SNMP
version 1.
Enter the Get Community string, which is the password for the
incoming Get- and GetNext- requests from the management station.
The Get Community string is only used by SNMP managers using
SNMP version 2c or lower.