S
ERVICE
Warning:
High voltage! Do not remove the rear panel. There are no user-
serviceable parts inside.
F
U S E R E P L A C E M E N T
The Atomic 3000 uses a 20 amp time-delay fuse for protection against current
overload. If the power diode does not light when power is applied, the fuse may
be spent. If the fuse blows repeatedly, there is a fault with the unit that requires
service by a Martin technician.
Never bypass the fuse or replace it with one of another size or rating.
Replacement fuses may be ordered by P/N 05020040.
To replace the fuse
1 Disconnect the fixture from AC power.
2 Unscrew the fuse holder, located on the side plate nearest the power cord.
Remove the spent fuse from the holder and replace it with an identical 20
amp 6.3 x 32 mm time-delay fuse.
3 Replace the fuse holder in the side plate.
F I R M W A R E U P D A T E S
If you suspect that the firmware installed on your Atomic 3000 has become
corrupted, please contact your Martin dealer for assistance.
Atomic 3000 user manual

Service

7
23