Page 2
Important note Before operating the device, you must read, understand, and follow all instructions, warnings, cautions, and legal disclaimers. Důležitá poznámka Před použitím zařízení si přečtěte veškeré pokyny, upozornění, varování a vyvázání se ze záruky, ujistěte se, že jim rozumíte, a řiďte se jimi.
Table of contents Disclaimers ..................1 Legal disclaimer ............... 1 U.S. Government Regulations............1 Patents ................... 1 Quality assurance ..............1 Third-party licenses..............1 Usage statistics ................ 1 Copyright ................1 Safety information ................2 Notice to user ...................6 Online documentation..............6 Register your camera..............
Page 4
Table of contents Operating the laser distance meter ..........22 7.5.1 General..............22 7.5.2 Procedure ..............22 Measuring areas..............23 7.6.1 General..............23 7.6.2 Procedure ..............23 Connecting external devices and storage media ......24 Moving files to a computer ............24 Programmable button ..............
Page 5
Table of contents 10.3.2 Manual adjustment by touching the screen ......51 10.3.3 Manual adjustment by using the navigation pad ....52 10.3.4 Manual adjustment in Level, Span mode ......52 10.3.5 Manual adjustment in Level, Max, Min mode ...... 53 10.4 Changing the camera temperature range ........
Page 6
Configuring Wi-Fi ................89 20.1 Setting up a wireless access point ..........89 20.2 Connecting the camera to a WLAN ..........89 Fetching data from external FLIR meters ..........90 21.1 General ................90 21.2 Technical support for external meters .......... 90 21.3...
Page 7
Table of contents About FLIR Systems ..............105 27.1 More than just an infrared camera ..........106 27.2 Sharing our knowledge ............106 27.3 Supporting our customers............107 #T810587; r. AA/74078/74713; en-US...
WARNING Applicability: Digital devices subject to 15.21. NOTICE: Changes or modifications made to this equipment not expressly approved by FLIR Systems may void the FCC authorization to operate this equipment. WARNING Applicability: Digital devices subject to 2.1091/2.1093/KDB 447498/RSS-102.
Page 10
High temperatures can cause damage to the camera. CAUTION Do not attach the batteries directly to a car’s cigarette lighter socket, unless FLIR Systems supplies a specific adapter to connect the batteries to a cigarette lighter socket. Damage to the batteries can occur.
Page 11
Safety information CAUTION Do not put the battery on or near fires, stoves, or other high-temperature locations. Damage to the bat- tery and injury to persons can occur. CAUTION Do not solder directly onto the battery. Damage to the battery can occur. CAUTION Do not use the battery if, when you use, charge, or put the battery in storage, there is an unusual smell from the battery, the battery feels hot, changes color, changes shape, or is in an unusual condition.
Page 12
Safety information Note The encapsulation rating is only applicable when all the openings on the camera are sealed with their correct covers, hatches, or caps. This includes the compartments for data storage, batteries, and connectors. #T810587; r. AA/74078/74713; en-US...
To register the camera, go to http://support.flir.com/camreg. To access the registration form, you must log in to your FLIR account or sign up for a new account. You will also need the serial number of your camera. The serial number is displayed by the registration wizard in the camera.
Notice to user 3.7 Note about authoritative versions The authoritative version of this publication is English. In the event of divergences due to translation errors, the English text has precedence. Any late changes are first imple- mented in English. 3.8 Disposal of electronic waste Electrical and electronic equipment (EEE) contains materials, components and substan- ces that may be hazardous and present a risk to human health and the environment when waste electrical and electronic equipment (WEEE) is not handled correctly.
• The communication protocol, or method, between the camera and your device (e.g., SD card reader, HDMI, Ethernet, USB, or FireWire). • Device type (PC/Mac/iPhone/iPad/Android device, etc.). • Version of any programs from FLIR Systems. • Full name, publication number, and revision number of the manual. 4.3 Downloads...
8. Pull the trigger to save an image. 9. When you have completed the inspection, connect the camera to a computer using the USB cable. 10. Import the images into a FLIR Thermography software and create an inspection report. 5.1 To keep in mind •...
Camera overview 6.1 View from the front 1. Laser distance meter. 2. Infrared lens. 3. Focus ring. 4. Autofocus button. 5. Trigger. 6. Lamp for the digital camera (left and right sides). 7. Digital camera. 8. Attachment point for the hand strap bracket (left and right sides). 9.
Camera overview 6.2 View from the rear 1. Cover for the USB connector and memory card slot. 2. Microphone. 3. Speaker. 4. Touch-screen LCD. 5. Image archive button. 6. Programmable button. 7. Button to operate the laser. 8. Back button. 9.
Camera overview 6.3.1 Laser transmitter and receiver 1. Laser transmitter. 2. Laser receiver. 6.3.2 Difference in position This figure shows the difference in position between the laser transmitter and the optical center of the infrared lens. 2. This item is dependent on the camera model. #T810587;...
Camera overview 6.3.3 Laser warning label A laser warning label with the following information is attached to the camera: 6.3.4 Laser rules and regulations Wavelength: 650 nm. Maximum output power: 1 mW. This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No.
Camera overview 1. Temperature scale button. 2. Measurement parameters button. 3. Image mode button. 4. Measurement button. 5. Color button. 6. Settings button. 7. Main menu. 8. Submenu. 6.4.3 Status icons and indicators Battery status indicator. • When the battery status is 20–100%, the indicator is white. •...
Camera overview 1. Battery status indicator. 2. Memory card storage status indicator. 3. • Wi-Fi button: Touch to enable/disable Wi-Fi. See also section 20 Configuring Wi- • Bluetooth button: Touch to enable/disable Bluetooth. See also section 19 Pairing Bluetooth devices. •...
Camera overview 6.5 Navigating the menu system You can navigate the menu system in two ways: • Using your finger or a stylus pen specially designed for capacitive touch usage. • Using the navigation pad and the back button 6.5.1 Navigating using the navigation pad You navigate the menu system by using the navigation pad and the back button: •...
Handling the camera 7.1 Charging the battery 7.1.1 General • Before starting the camera for the first time, charge the battery for 2 hours using the stand-alone battery charger. • Select a mains socket that is near the equipment and easily accessible. 7.1.2 Using the stand-alone battery charger to charge the battery 1.
Handling the camera 4. Connect the USB connector of the USB battery charger to the USB-C connector in the connector bay of the camera. 5. To check the status of the battery charging, do one of the following: • If the camera is turned on: Place your finger at the top of the screen and swipe down.
Handling the camera 2. Connect a USB cable to the USB-C connector in the connector bay. Connect the oth- er end of the USB cable to the computer. Note • To charge the camera, the computer must be turned on. •...
Handling the camera 7.4 Adjusting the thermal camera focus It is very important to adjust the focus correctly. Incorrect focus adjustment affects how the image modes work. It also affects the temperature measurement. You can adjust the camera focus by rotating the focus ring or by pushing the autofocus button.
Handling the camera Note • You can also assign the autofocus function to the programmable button. For more in- formation, see section 7.9 Programmable button. • Autofocus is not supported by all camera models. 7.4.2.1 Autofocus method When autofocusing, the camera can use one of the following focus methods: •...
Handling the camera Note • Before you can enable continuous autofocus, you need to enable the laser and select laser as focus method. See section 7.4.2.1 Autofocus method. • When continuous autofocus is enabled, it is not possible to manually adjust the focus by rotating the focus ring.
Handling the camera 7.6 Measuring areas 7.6.1 General Note The availability of this feature is dependent on the camera model. The distance measured by the laser distance meter can be used as the basis for area calculations. A typical application is to estimate the size of a damp stain on a wall. To measure the area of a surface, you need to lay out a box or circle measurement tool on the screen.
Handling the camera 5. Hold the camera perpendicular to the target. Push and hold the laser button 6. The calculated area is displayed in the result table. 7.7 Connecting external devices and storage media You can connect the following external devices and media to the camera: •...
Page 32
• Move the files to the computer using a drag-and-drop operation. Note Moving a file using a drag-and-drop operation does not delete the file in the camera. • Import the images into a FLIR Thermography software. #T810587; r. AA/74078/74713; en-US...
Handling the camera 7.9 Programmable button You can assign different functions to the programmable button. You can, for example, use the programmable button to easily switch between two settings you use often. You can also choose to define two different setups for saving and previewing: the ordinary setup for the trigger (which is defined by the Save options and storage settings, see sec- tion 22.4 Save options &...
Handling the camera • Switch Auto <> Manual temperature scale: Switch between automatic or manual im- age adjustment mode. For more information, see section 10.3 Adjusting the infrared image. • Autofocus : One-shot autofocus of the infrared camera. • Continuous autofocus : Switch between the enabled/disabled continuous autofocus functions.
Handling the camera 2. Select (Settings) and push the navigation pad. This displays the Settings menu. 3. Use the navigation pad to select Device settings > Lamp & laser. 4. To use the camera lamp as a flash, do one of the following: •...
Handling the camera 7.11.1 Mounting the hand strap 1. Fit the upper part of the hand strap into the bracket. 2. Fit the bracket in place on the camera and tighten the screw with the supplied Torx key. #T810587; r. AA/74078/74713; en-US...
Page 37
Handling the camera 3. Thread the loose strap through the attachment point at the base of the camera. Se- cure the strap with the hook-and-loop fastener. #T810587; r. AA/74078/74713; en-US...
Handling the camera 7.12 Lanyard strap To mount the lanyard strap, do the following: 1. Remove the camera battery. #T810587; r. AA/74078/74713; en-US...
Handling the camera 2. Starting with the FLIR logo part, thread the lanyard strap through the attachment point at the base of the camera. 3. Pull the entire lanyard strap through the attachment point until it stops. 7.13 Wrist strap The wrist strap can also be used to attach a carabiner to the camera.
Handling the camera 2. Fold the wrist strap. Make sure that the part with the FLIR logo faces away from the bend. 3. Thread the bent wrist strap through the attachment point at the base of the camera. 4. Pull the entire wrist strap through the attachment point until it stops.
Handling the camera 7.15 Changing camera lenses Applicability: Camera models with an exchangeable lens. Note If the new lens has not been used with the camera before, the lens–camera com- bination must be calibrated after the lens has been mounted. See section 7.16 Calibrat- ing the lens–camera combination for information on how to do this.
Page 42
Handling the camera 2. Carefully pull out the lens. 3. The infrared detector is now fully exposed. Do not touch this surface. If you see dust on the detector, follow the instructions in 23.3 Infrared detector. #T810587; r. AA/74078/74713; en-US...
Page 43
Handling the camera 4. Make sure that the inner ring of the camera lens is fully in its open position. • Correct: The tooth (1) is in its end position at the black stop pin (2). • Wrong: You must rotate the inner ring until the tooth (1) reaches the black stop pin (2).
Before a new lens can be used with the camera, the lens–camera combination must be calibrated. This is a process that previously had to be performed by a FLIR service department, but for the FLIR Exx series the calibration can be performed by the user. This feature is called AutoCal.
Handling the camera 7.16.2 AutoCal procedure 1. Dip the calibration target in water for 1 second and let the excess drip off. 2. Tape or hang the calibration target on a wall. 3. Mount the new lens on the camera according to the procedure in section 7.15 Changing camera lenses.
Handling the camera 4. From a distance of 2 m (6.6 ft.), aim the camera toward the crosshair, using the laser pointer. The camera will take a picture automatically. Note Make sure the camera’s optical path is perpendicular to the calibration target. See the image below.
The image *.jpg file is fully radiometric and saved lossless, which enables full post-proc- essing in image analysis and reporting software from FLIR Systems. There is also a reg- ular *.jpg component (lossy) for convenient viewing in non-FLIR Systems software (e.g., Microsoft Explorer).
Saving and working with images Some FLIR Thermography software has the ability to process UltraMax images. Other FLIR software will treat the image as a regular image. To configure the camera for UltraMax, select (Settings) > Save options & storage >...
Saving and working with images 4. Do one of the following: • To save the image, pull the trigger. • To exit preview mode without saving, push the back button 8.4 Opening a saved image When you save an image, the image file is stored on the memory card. To display the im- age again, open it from the image archive (Gallery).
Saving and working with images 8. Push the navigation pad. This displays a context menu. • Select (Cancel) to exit edit mode. • Select (Measurement parameters) to change the global parameters. • Select (Image mode) to change the image mode. •...
Saving and working with images To digitally zoom an image, do the following: • Zoom in: Touch the screen with two fingers and spread the fingers apart. • Zoom out: Touch the screen with two fingers and pinch the fingers together. 8.8 Deleting images You can delete image files from the memory card.
Working with the image archive 9.1 General When you save an image or video clip, the camera stores the image/video file in the im- age archive on the memory card. You can open an image in the image archive and, for example, select another image mode, apply color alarms, and add measurement tools.
Working with the image archive 9.4 Renaming a folder You can change the name of the folders in the archive. The active folder cannot be renamed. Follow this procedure: 1. Push the image archive button . This displays the Gallery. 2.
Working with the image archive 9.7 Deleting a folder You can delete a folder in the archive. The active folder cannot be deleted. Follow this procedure: 1. Push the image archive button . This displays the Gallery. 2. On the top toolbar, select the icon and push the navigation pad.
Working with the image archive 5. On the right toolbar, select the icon and push the navigation pad. This displays a dialog box. 6. To delete the selected items, select Delete and push the navigation pad. 9.10 Deleting all files You can delete all image and video files from the memory card.
Achieving a good image 10.1 General A good image depends on several different functions and settings, although some func- tions and settings affect the image more than others. These are the functions and settings that you need to experiment with: •...
Page 57
Achieving a good image In automatic mode, the camera continuously adjusts the level and span for the best im- age presentation. The colors are distributed based on the thermal content of the image (histogram color distribution). The temperature scale to the right of the screen shows the upper and lower temperatures of the current span.
Achieving a good image Automatic Manual 10.3.2 Manual adjustment by touching the screen 10.3.2.1 General The touch functionality for manual image adjustments is enabled/disabled by a setting. Select (Settings) > Device settings > User interface options > Manual adjustment us- ing touch >...
Achieving a good image 10.3.2.3 Auto-adjusting the image in manual mode In manual image adjustment mode, you can auto-adjust the image by touching the screen. The image will be auto-adjusted based on the thermal content of the area around the touched point. The top and bottom levels in the temperature scale will be set to the maximum and minimum temperatures in that area.
Achieving a good image 3. Select (Manual) and push the navigation pad. 4. Push the navigation pad up/down to increase/decrease the level. 5. Push the navigation pad left/right to increase/decrease the span. 10.3.5 Manual adjustment in Level, Max, Min mode Note This procedure assumes that you have configured the camera for manual image adjustments in Level, Max, Min mode.
Page 61
Achieving a good image This table explains the different types of color palettes. Iron Arctic Rainbow Rainbow high contrast White hot Black hot Lava Follow this procedure: 1. Push the navigation pad to display the menu system. 2. Select (Color) and push the navigation pad. This displays a submenu. 3.
Achieving a good image 4. Push the navigation pad to confirm and exit the menu mode. 10.6 Changing the measurement parameters For accurate measurements, it is important to set the measurement parameters: • Emissivity. • Reflected temperature. • Object distance. •...
Page 63
Achieving a good image You can choose to hide all camera overlay by pressing the programmable button. Image with camera overlay and image overlay Image with all overlay hidden. information. Follow this procedure: 1. Push and hold the programmable button. This displays the Programmable button menu.
• For the Thermal MSX, Thermal, and Picture in picture image modes, all thermal and visual information is stored when an image is saved. This means that you can edit the image later, in the image archive or in a FLIR Thermography software, and select any of the image modes.
Working with image modes Thermal MSX Thermal Digital camera Picture in picture 11.3 Selecting an image mode Follow this procedure: 1. Push the navigation pad to display the menu system. 2. Select (Image mode) and push the navigation pad. This displays a submenu. 3.
Working with measurement tools 12.1 General To measure a temperature, you can use one or more measurement tools, e.g., a spot- meter or a box. 12.2 Adding/removing measurement tools Follow this procedure: 1. Push the navigation pad to display the menu system. 2.
Working with measurement tools 2. Select (Measurement) and push the navigation pad. This displays a submenu. 3. Use the navigation pad to select (User preset 1) or (User preset 2). 4. Push and hold the center of the navigation pad. This displays the Edit user preset menu.
Working with measurement tools 5. When completed, push the navigation pad and select (Done). 6. Push the navigation pad to confirm and exit the menu mode. 12.4.3 Moving and resizing a box or circle tool Note You can also move and resize the measurement tool by touching the screen. Follow this procedure: 1.
Working with measurement tools • Reflected temperature, which is used when compensating for the radiation from the surroundings reflected by the object into the camera. This property of the object is called “reflectivity.” • Emissivity, i.e., how much radiation an object emits, compared with the radiation of a theoretical reference object at the same temperature (called a “blackbody”).
Working with measurement tools 4. Push the navigation pad to display a dialog box. 5. Use the navigation pad to change the parameter. 6. Push the navigation pad to confirm and exit the menu mode. 12.5.4.2 Changing local parameters You can change the local parameters for a measurement tool. A P next to the measurement tool on the screen indicates that local parameters have been activated for the tool.
Working with measurement tools Follow this procedure: 1. To select the measurement tool, touch the tool on the screen. The tool is now dis- played with one or more handles. 2. Push the navigation pad—or touch and hold the tool. This displays a context menu. 3.
Working with measurement tools Note • You can set up a difference calculation when previewing an image or when editing an image in the archive. • Depending on the camera model, you can also set up a difference calculation when defining user presets or by selecting the measurement tool Hot spot - Spot.
Page 73
Working with measurement tools 3. Select (Set alarm on spot) and push the navigation pad. This displays a dialog box. 4. In the dialog box, you can define the settings for the alarm. • Alarm condition: The condition that triggers the alarm. Applicable values are Above, Below, or Off.
Page 74
Working with measurement tools 12.8.4.3 Setting up an alarm for a difference calculation Note • You can set up an alarm for a difference calculation when defining user presets (de- pending on the camera model), or when editing an image in the archive. •...
Working with color alarms and isotherms 13.1 Color alarms By using color alarms (isotherms), anomalies can easily be discovered in an infrared im- age. The isotherm command applies a contrasting color to all pixels with a temperature above, below, or between the set temperature levels. The camera also features isotherm types that are specific to the building trade: condensation and insulation alarms.
Working with color alarms and isotherms 13.1.1 Setting up above, below, and interval alarms 1. Push the navigation pad to display the menu system. 2. Select (Color) and push the navigation pad. This displays a submenu. 3. Use the navigation pad to select one of the following: •...
Page 77
Working with color alarms and isotherms 4. Push the navigation pad. This displays a dialog box where you can define the settings for the alarm. For the Condensation alarm, the following parameters can be set: • Atmospheric temperature: The current atmospheric temperature. •...
Annotating images 14.1 General You can save additional information with an infrared image by using annotations. Annota- tions make reporting and post-processing more efficient by providing essential informa- tion about the image, e.g., conditions and information about where an image is taken. Annotations are added to the image file, and can be viewed and edited in the image ar- chive, and also when moving files from the camera to reporting software on the computer.
FLIR Thermography software. 14.3.1.1 Manually creating a table template A text comment file (*.tcf) is an annotation format that is proprietary to FLIR Systems. It defines a table structure that can be used to add text table annotations to FLIR images.
A voice annotation is an audio recording that is saved to the infrared image file. The re- cording can be played back in the camera, and in image analysis and reporting software from FLIR Systems. The voice annotation is recorded using the built-in microphone. You can also use a Blue- tooth-enabled headset.
Annotating images Follow this procedure: 1. Open the image in the image archive. 2. Push the navigation pad to display the top toolbar. 3. On the top toolbar, select the icon and push the navigation pad. 4. On the right toolbar, select the icon and push the navigation pad.
Page 82
Annotating images 4. On the right toolbar, select the icon and push the navigation pad. 5. You are now in sketch mode. Draw the sketch by touching the screen. 6. (Optional step.) Push the navigation pad. This displays a context menu. Do one or more of the following: •...
Programming the camera (time- lapse) Note The availability of this feature is dependent on the camera model. You can program the camera to save images periodically (time-lapse). Follow this procedure: 1. Push the navigation pad to display the menu system. 2.
• Radiometric storage (*csq) : A *.csq file supports full radiometry but is only supported by FLIR Systems software. The file does not include any visual image information. With this setting, only Thermal image mode is supported when recording video. If any other image mode is active when Video recording mode is selected, the camera will auto-switch to Thermal image mode.
1. Prepare the inspection route file, using one of the following methods: • FLIR thermography software that has inspection route support. • Your own solution. The FLIR Thermal SDK can be used to build your own export/ import software or to interface your existing asset management system.
Inspection Route • Next arrow Tap to go to the next inspection point. • Document icon This icon is displayed if there is a description and/or comment available for the inspec- tion point. A description comes from the inspection route file and can, for example, in- clude instructions or reminders for the inspection point.
Inspection Route Figure 17.1 shows an example of the inspection list: • The first inspection route is completed and locked, which is indicated by the check mark to the right. • The second inspection route has started. It includes a total of 91 inspection points, and one of them has been inspected.
Inspection Route 1. The current point indicator displays which inspection point to inspect. 2. To view a description of the inspection point, e.g., instructions or reminders, tap the document icon. Note The document icon is only displayed if there is a description and/or comment available for the inspection point.
Inspection Route 17.3.3.1 Setting the status 1. Tap the current point indicator. This displays a drop-down menu. 2. Tap the status you want to set. The set status is indicated by a check mark in the menu and by a color in the current point indicator. Note •...
Inspection Route 5. To make changes to an inspection point, tap the inspection point in the list. This takes you to the live view for that inspection point. Note You can only make changes to inspection points in unlocked inspection routes.
The inspection route file can be created using one of the following methods: • FLIR thermography software that has inspection route support. • Your own solution. The FLIR Thermal SDK can be used to build your own export/im- port software or to interface your existing asset management system.
Page 92
Inspection Route 3. Select one of the following: • Create an example Inspection route: This creates an example XML file with a mul- ti-level structure on the memory card. • Create an empty Inspection route: This creates a basic XML file on the memory card.
Screening alarm The screening alarm can be used to detect temperature anomalies in a series of in- spected objects in a similar/fixed setup. 18.1 General The basics of the screening alarm is to first build up a base of reference temperature samples.
Screening alarm 18.2.2 Record reference samples Before the screening can start, you must record reference samples. These are used to calculate the reference temperature average. You record the reference samples by screening 10 inspection objects. Make sure these objects have a normal temperature. 1.
• You can remove a device by selecting the device and then selecting Unpair device. • After adding a METERLiNK device, such as the FLIR MR77 or FLIR DM93, the result from the meter will be visible in the result table and stored with the images. For more information, see section 21 Fetching data from external FLIR meters.
Configuring Wi-Fi Depending on your camera configuration, you can connect the camera to a wireless local area network (WLAN) using Wi-Fi, or let the camera provide Wi-Fi access to other devices. You can connect the camera in two different ways: •...
The live value is displayed with a dotted outline. If the screen display for values is full, it is still possible to add more values from the FLIR meter. Added values are then indicated by a box with a number that counts up each time a new value is added.
Fetching data from external FLIR meters 4. On the FLIR meter, choose the quantity that you want to use (voltage, current, resist- ance, etc.). Refer to the user documentation for the meter for information on how to do this. Results from the meter will now automatically be displayed in the result table in the top left corner of the infrared camera screen.
Camera settings The Settings menu includes the following: • Recording mode. • Connections. • Camera temperature range. • Save options & storage. • Device settings. 22.1 Recording mode The Recording mode is used to select: • Single shot: This setting enables single shot mode. In this mode, you save an image by pulling the trigger.
◦ Radiometric storage (*.csq) : A CSQ file supports full radiometry but is only sup- ported by FLIR Systems software. The file does not include any visual image infor- mation. With this setting, only Thermal image mode is supported when recording video.
Camera settings • Delete all saved files...: This displays a dialog box where you can choose to perma- nently delete all the saved files (images and videos) from the memory card or to can- cel the delete action. 22.5 Device settings •...
Page 102
Camera settings ◦ Enable lamp & laser: This setting is used to enable the camera lamp and the laser. ◦ Enable lamp & laser + Use lamp as flash: This setting is used to enable the flash function. When the flash function is enabled, the camera lamp will flash when an image is saved.
Cleaning the camera 23.1 Camera housing, cables, and other items Use one of these liquids: • Warm water • A weak detergent solution Equipment: • A soft cloth Follow this procedure: 1. Soak the cloth in the liquid. 2. Twist the cloth to remove excess liquid. 3.
Page 104
Cleaning the camera Note • This section only applies to cameras where removing the lens exposes the infrared detector. • In some cases the dust cannot be removed by following this procedure: the infrared detector must be cleaned mechanically. This mechanical cleaning must be carried out by an authorized service partner.
CE Declaration of conformity [See next page] #T810587; r. AA/74078/74713; en-US...
Page 108
SE-187 15 Täby, Sweden This declaration of conformity is issued under the sole responsibility of the manufacturer. The object of the declaration: FLIR E53 /E54 /E75 /E76 /E85 /E86 / E95 /E96-series (Product Model Name FLIR-E7850). The object of the declaration described above is in conformity with the relevant Union harmonisation...
26.3 Camera calibration at FLIR Systems Without calibration, an infrared camera would not be able to measure either radiance or temperature. At FLIR Systems, the calibration of uncooled microbolometer cameras with a measurement capability is carried out during both production and service. Cooled cam- eras with photon detectors are often calibrated by the user with special software.
The calibration information, no matter if the calibration is done by FLIR Systems or the user, is stored in calibration curves, which are expressed by mathematical functions. As...
About calibration Calibration is also a prerequisite for adjustment, which is the set of operations carried out on a measuring system such that the system provides prescribed indications corre- sponding to given values of quantities to be measured, typically obtained from measure- ment standards.
• Extech Instruments (2007) Figure 27.1 Patent documents from the early 1960s FLIR Systems has three manufacturing plants in the United States (Portland, OR, Boston, MA, Santa Barbara, CA) and one in Sweden (Stockholm). Since 2007 there is also a manufacturing plant in Tallinn, Estonia.
27.1 More than just an infrared camera At FLIR Systems we recognize that our job is to go beyond just producing the best infra- red camera systems. We are committed to enabling all users of our infrared camera sys- tems to work more productively by providing them with the most powerful camera–...
27.3 Supporting our customers FLIR Systems operates a worldwide service network to keep your camera running at all times. If you discover a problem with your camera, local service centers have all the equipment and expertise to solve it within the shortest possible time.
Page 115
Disclaimer Specifications subject to change without further notice. Models and accessories subject to regional market considerations. License procedures may apply. Products described herein may be subject to US Export Regulations. Please refer to exportquestions@flir.com with any questions. Publ. No.: T810587...