Electrical Data; Heating And Cooling Application Wiring Diagram; Disconnect Switch And Furnace - Carrier 58MVP Installation, Start-Up, And Operating Instructions Manual

Series 180 4-vvay mumtipoise dkect-vent variabme-capacity condensing gas furnace
Table of Contents

Advertisement

Table 4--EiectricN
Data
UNIT
SIZE
[',_AXJMUM FUSE OR
CKT BKR AMP$**
VOLTS--
HERTZ--
PHASE
115--60--1
115--60--1
115--60--1
115--60--1
115--60--1
115--60--1
OPERATING
VOLTAGE
RANGE
Maximum*
Minimum*
127
104
127
104
127
104
127
104
127
104
127
104
MAXIMUN
UNiT
AMPS
8.9
8.9
8.9
13.8
13.8
13.8
MINIMUM
WRRE
SIZE
14
14
14
12
12
12
MAXBMUM WIRE
LENGTH (FT)_:
31
31
31
32
32
32
040-14
15
060-14
15
080-14
15
080-20
20
100-20
20
t20-80
20
* Permissible
limits of voltage range at which unit will operate satisfactorily.
T Unit ampadty
= 125 percent of largest operating component's
full load amps plus 100 percent of aH other potential
operating components'
(EAC, humidifier,
etc.) fun
load amps
$ Length shown is as measured
1 way along wire path between
unit and service panel for maximum 2 percent voltage drop.
*_ Time-delay
type is recommended.
115-V
SINGLE
PHASE
....
FIELD 24-V WIRING
....
FIELD 115-, 208/230-, 460-V WIRING
--
FACTORY 24-V WIRING
--
FACTORY 115-, 208/230-, 460-V WIRING
THERMOSTAT
TERMINALS
FIELD-SUPPLIED
DISCONNECT
CONDENSING
UNIT
208/230- OR
460-V
208/230-V
SINGLE
PHASE
NOTES:
1. Connect Y or Y/Y2 terminaI as shown for proper cooling operation.
2. Proper polarity must be maintained for 115-v wiring.
3. Use W2 with 2-stage thermostat when zoning.
4. If any of the original wire, as supplied, must be replaced, use
same type or equivalent wire.
5. Some thermostats require a "C" terminal connection as shown.
A98325
Fig. 28--Heating
and Cooling
Application
Wiring
Diagram
[TNIT MAY NOT OPERATE
Failure to %llow this caution may result in intem_ittent unit
operation,
Furnace control must be grounded for proper operation or
control
will
tock
out,
(ontrol
is
grounded
through
green yellow wire connected
to gas valve and burner box
screw,
115-V WIRING
Be%re
proceeding
with electrical
cormections,
make
certain
that
voltage,
fi'equency,
and phase
con'espond
to that
specified
on
furnace
rating
plate, Also,
check
to be sure that sma'ice provided
by power
supply
is sufficient
to handle
load
imposed
by this
equipment
Refer to rating plate or Table 4 for equipment
electrical
specifications
2i
ELECTRIC
DISCONNECT
SWITCH
®
A93033
Fig. 29--Disconnect
Switch and Furnace
Make al! electrical
connections
in accordance
with National
Electlical Code (NEC) ANSI NFPA 70-2002 and any local codes
or ordinances that might apply For (anadian
installations,
all
electlical connections must be made in accordance with Canadian
Electrical (7ode CSA C22,1 or authorities having jurisdiction
Field=supplied wiring shall conform with the limitations of 63_>F
(33°C) rise