Heat Pump; Component Test; Set Gas Input Rate; Continuous Blower Speed Selection From Thermostat - Carrier 58MVP Installation, Start-Up, And Operating Instructions Manual

Series 180 4-vvay mumtipoise dkect-vent variabme-capacity condensing gas furnace
Table of Contents

Advertisement

issatisfied,
the blower motor BLWM willoperate
anadditional
90
seconds at high-cooling
airflow bei\_re t lansitioning backto
continuous-blower
airflow.
When t he RtoGcircuit isopened,
the blower motor BLWM will
continue operating
foran additional 5seconds,
ifnoother flmction
requires blower motor BLWM operation
Continuous
Blower Speed Selection fromThermostat
Toselect different continuous-blower
speeds fi'om the room
thermostat,
momentarily
turnofftheFANswitch orpush°
button onthe room themaostat
for1 =3 seconds
after t !_e blower
motor BLWM isoperating.
The fl/mace control CPU willshift
the continuous-blower
airflow fl'om the fi_ctory setting tothe
nexthighest CFselection airflow asshown i n Fig.50.
Momentarily
mining o ffthe FAN switch again a tthe thermo=
stat w ill shiftthecontinuous-blower
airflow uponemore
increment.
If yourepeat thisprocedure
enough, youwill
eventually
shift t he continuous-blower
airflow tothelowest
CFselection asshown i n Fig.50.Theselection canbe
changed
as many t imes as desired and isstored inthe memory
tobeautomatically
used f bllowing apower intem/ption.
HEAT PUMP
See Fig. 5 6=59 forflaermostat
connections.
When i nstalled with aheat pump, the/\1mace
contlol automatically
changes
the timing s equence
toavoid l ong blower ofttimes d uring
demand defl'ost cycles. Whenever
W/W1 isenergized
along w ith
Y1orYY2,the furnace control CPU willtransition
toorbring o n
the blower motor BLWM atcooling airflow, tow-heat airflow, or
themidrange
airflow, whichever
isthe lowest. The blower motor
BLWM willremain on until t he main b urners ignite, then shut OFF
and remain OFF fbr
25 seconds
before
coming
back on at heating
airflow.
When
the W/W1
input
signal
disappears,
the
Nrnace
control begins
a normal
inducer
post-purge
period
while changing
the blower
airflow.
If YY2
input
is still energized,
the Nrnace
control
CPU will tlansition
the blower
motor BLWM
airflow
to
cooling
airflow.
If Y/Y2
input signal disappears
and the YI input
is still
energized,
the Nmace
contlol
CPU
will
transition
the
blower
motor
BLWM
to low=cooling
airflow.
If both the Y1 and
Y/Y2
signals
disappear
at the same time, the blower
motor BLWM
will remain
on at low-heat
airflow
for the selected
blower=OFF
delay
period.
At the end of the blower-OFF
delay,
the blower
motor
BLWM
will shut OFF unless
G is still energized,
in which
case the blower
motor
BLWM
will operate
at continuous
blower
airflow.
COMPONENT
TEST
The furnace
features
a component
test system
to help diagnose
a
system
problem
in the case of a component
failure
To initiate
the
component
test procedure,
ensure
that
there
are
no thermostat
inputs
to the control
and all time
delays
have expired.
Turn
on
setup switch
SWI°6
(See Fig. 32.)
NOTE:
The component
test feature
will not operate
if the control
is receiving
any them_ostat
signals
or until
all time
delays
have
expired.
The component
test sequence
is as follows:
a. The fimaace control
CPU turns the inducer
motor IDM ON
at n_edium
speed
and keeps
it ON through
step c.
b. After waiting
15 seconds,
the fl/mace
contlol
CPU rams
the hot surface
igniter
ON _br 15 seconds,
then OFF.
c. The
fl/mace
control
CPU
then
turns
the blower
motor
BLWM
ON at midrange
airflow
_br 15 seconds,
then OFF.
d. After shutting
the blower
motor BLWM
OFF, the furnace
contlol
CPU
shuts the inducer
motor IDM
OFF.
NOTE:
The EA(
terminals
are
energized
when
the blower
is
operating.
After the component
test is completed,
1 or more status codes (11,
25, 41, or 42) will flash. See Sela'ice
Label on blower
access panel
or Service/Stares
Code Instructions
fbr explanation
of stares codes.
NOTE:
To repeat
component
test,
turn setup
switch
SWI=6
to
OFF and then back ON.
Step
6--Adjustments
SET GAS INPUT
RATE
Furnace
gas input rate on rating plate is %r installations
at altitudes
up to 2000 ft.
In the U.S.A,
the input rating
for altitudes
above 2000 ft must be
reduced
by 2 percent
_br each 1000 ft above sea tevel
In (anada,
the input
rating
must
be
derated
by 5 percent
for
altitudes
of 2000 ft to 4500 ft above sea level.
Adjust
manifold
pressure
to obtain
input rate.
Furnace
input
rate
n-rest be within
_+2 percent
of input
rate
on
furnace
rating
plate.
1. Determine
natural
gas orifice
size and manifbld
pressure
_br
correct
input.
a. Obtain
average
heat value (at installed
altitude)
from local
gas supplier.
b. Obtain
average
specific
gravity
fl'om local
gas supplier.
c. Verify
Nmace
model
Table
11 can only be used _br model
58MVP
Furnaces.
d. Find installation
altitude
in Table
11.
NOTE:
For Canadian
altitudes
of 2000
to 4500
fl, use U.S.A.
altitudes
of 2001 to 3000 ft in Table
11.
e
Find closest
natural
gas heat value
and specific
gravity
in
Table
11
£ Follow
heat value
and
specific
gravity
lines
to point
of
intersection
to find
orifice
size
and low-
and
high-heat
manifbld
pressure
settings
for proper
operation
EXAMPLE:
(0
2000 fi altitude)
Heating
value
1050 Bmicu
ft
Specific
gravity
0.62
Therefbre:
Orifice
No. 45
Manifold
pressure:
3.8-in.
wc for high heat
1.6-in. wc for tow heat
* Furnace
is shipped
with No. 45 orifices
In this example,
all main burner
orifices
are the cotxect size and do not need
to be changed
to obtain
proper
input rate
42
g. Check
and verify
burner
orifice
size in furnace.
NEVER
ASSUME
ORIFI(E
SIZE;
ALWAYS
(HE(K
AND
VERIFY.
Adjust
manifold
pressure
to obtain
input
rate
a Remove
burner
enclosure
fiont
NOTE:
Manifold
pressure
MUST
always
be measured
with the
burner
box cover
REMOVED
b. Remove
regulator
seal caps that conceal
adjustment
screws
for low= and high=heat
gas valve regulators.
(See Fig. 62)
c Move
setup switch
SWI=2
on control
center
to ON posi=
tion
(See Fig
32.) This keeps
fl/mace
locked
in low-heat
operation
d. Jumper
R and W/W1
fl'*ermostat
connections
on control
to
start fl_rnace.