Electrical Connections; Maximum Capacity Of Pipe; Removing Bottom Closure Panel; Typical Gas Pipe Arrangement - Carrier 58MVP Installation, Start-Up, And Operating Instructions Manual

Series 180 4-vvay mumtipoise dkect-vent variabme-capacity condensing gas furnace
Table of Contents

Advertisement

Z
FRONT FILLER
PANEL
BOTTOM
CLOSURE
PANEL
A93047
Fig. 26--Removing
Bottom
Closure
Panel
Tab{e 3--Maximum
Capacity
of Pipe*
INTERNAL
DRAMETER
(IN.)
0.622
0.824
1.049
1.380
1.610
Cubic ft of gas per hr for gas
a pressure drop of 0.5-in. wc
Table 9-2 NFPA 54-2002
LENGTH OF PIPE (FT)
10
20
30
40
50
175
120
97
82
73
360
250
200
170
151
680
465
375
320
285
1400
950
770
660
580
2100
1460
1180
990
900
_ressures of 05 psig(14-in,
wc) orless,
and
based on a 0.60 specific gravity gas)Ref:
NOMINAL
IRON
PiPE
SRZB
(IN.)
1/2
3/4
1
1-1/4
1-112
--F
FIRE
OR EXPLOSION
HAZARD
Failure
to %l]ow this warning
could result
in fire, explosion,
personal
injury,
or death
Connect
gas pipe to f_lmace using a backup
wrench
to avoid
damaging
gas controls
Gas valve shutoff
switch
MUST
be f_lcing fbp, vard or tilted
upward
Never
purge
a gas line into a combustion
chamber.
Never
test for gas leaks
with
an open
flame.
Use a commercially
available
soap solution
made
specifically
for the detection
of
leaks to check
all connections
Use proper
length
of pipe
to avoid
stress
on gas control
manifbld
- If a flexible
connector
is required
or allowed
by authori V
having
jurisdiction,
black
iron
pipe
shall
be
installed
at
t\u'nace
gas valve
and extend
a mininmm
of 2 in. outside
furnace
casing.
Install
a sediment
trap in riser
leading
to _lmace.
Trap can be
installed
by
connecting
a tee to
riser
leading
to
furnace
so
straight-through
section
of tee is vertical
Then
connect
a capped
nipple
into lower end of tee. Capped
nipple
should extend
below
level
of gas
contlols.
Place
a ground
joint
union
between
gas
control
manifold
and manual
gas shutoff
valve.
(See Fig
27.)
GAS
SUPPLY
MANUAL
_/
]]
IR 00,R 0
f
A93324
Fig. 27--Typica!
Gas Pipe Arrangement
An accessible
manual
shutoff valve MLST
be installed
external
to
ft_rnace casing
and within
6 ft of _i_rnace. A 1i8oin. NPT plugged
tapping,
accessible
_br test gauge connection,
MUST
be installed
immediately
upstream
of gas
supply
connection
to ftlrnace
and
downstleam
of manual
shutoff
valve.
NOTE:
The gas valve inlet pressure
tap connection
is suitable
to
use as test gauge
connection
providing
test pressure
DOES
NOT
exceed
maximum
05
psig (14oin
wc) stated
on gas valve
(See
Fig
62.)
Piping
should
be pressure
and
leak
tested
in accordance
with
NFGC
in the United
States or NSCNGPIC
in (anada,
local,
and
national
plumbing
and gas
codes
before
the
furnace
has been
connecte&
If pressure
exceeds
05
psig (14oin
wc),
gas supply
pipe
must
be
disconnected
fiom
ftmaace
and
capped
be_bre
pressure
test
If test pressure
is equal to or tess than 05 psig ( 14oin wc), turn off
electric
shutoff
switch
located
on gas valve
before
test.
It is
recommended
that ground joint union be loosened
before pressure
testing.
After
all connections
have
been
made,
purge
lines
and
check
for leakage
at furnace
prior
to placing
it into service.
The
gas
supply
pressure
shall
be
within
the
maximum
and
minimum
inlet
supply
pressures
marked
on the rating
plate with
the t_/mace
burners
ON at HI-HEAT
and OFF.
Step
8--Electrical
Connections
See Fig
28 for field wiring
diagram
showing
typical
field
115-v
and 24-v wiring
Check all I:_cto_- and field etectIical
connections
for tightness
ELECTRICAL
SHOCK
HAZARD
Failure
to follow
this warning
could
result in personal
injury
or death.
Blower
access
door
switch
opens
115-v power
to furnace
contlol.
No component
operation
can occur. Do not bypass
or
close
switch
with panel removed.
2O