Bottom Closure Panel; Gas Piping; Filter Information - Carrier 58MVP Installation, Start-Up, And Operating Instructions Manual

Series 180 4-vvay mumtipoise dkect-vent variabme-capacity condensing gas furnace
Table of Contents

Advertisement

RETAINER
\
A93045
Fig. 24_FiRer
Installed
for Side Inlet
If installing
the filter
in the f:urnace blower
compartment,
deter-
mine
location
for
filter
and
relocate
filter
retaining
wire,
if
necessary.
See Table 2 to determine
correct
filter size for desired
filter location.
Table
2 indicates
filter
size, location,
and quantity
shipped
with
this
iqm_ace.
See Fig.
2 for location
and
size of
bottom
and side return=air
openings.
CUTS
AND
ABRASION
HAZARD
Failure
to %llow
this caution
may result
in minor
personal
injury
Use care when cutting
support
rods in filters to protect
against
flying pieces
and sharp rod ends. Wear safety glasses,
gloves,
and appropiate
protective
clothing
171/2-1N. WIDE
CASINGS
ONLY:
INSTALL
FELD-SUPPLIED
FILTER
FILLER
STRIP
UNDER
FILTER.
24 1/2"
rt4;
4
21-IN.WIDE
CASINGS
ONLY:
SUPPORT
RODS
(3)
EXTEND
1/4" ON EACH
SIDE OF FILTER
AND
REST
ON CASING
FLANGE
WASHABLE
FILTER
UNIT
MAY
NOT
OPERATE
Failure
to follow
this caution
may result
in intem_ittent
unit
operation
or peribm_aace
satisfaction.
For airflow
requirements
above
1800 CFM,
see Air Deliver-
table in Product
Data literature
fbr specific
use of single side
inlets. The use of both side inlets, a combination
of 1 side and
the bottom,
or the bottom
only will ensure
adequate
return air
openings
for airflow
requirements
above
1S00 CFM.
NOTE:
Side return-air
openings
can ONLY
be used in UPFLOW
configurations.
Install
filter(s)
as shown
in Fig. 24.
For bottom
return-air
applications,
filter
may need to be cut to fit
some I_urnace widths.
Install
filter
as shown
in Fig. 25.
NOTE:
Remove
and discard
bottom
closure
panel
when bottom
inlet is used,
Step
6--Bottom
Closure
Panel
These fire, aces are shipped
with bottom
closure
panel installed
in
bottom
return-air
opening.
This panel MUST be in place when side
remm
air is used.
TaNe 2--FHter
Information
AIR FILTER LOCATED BN BLOWER COMPARTMENT
Furnace
Filter Size (In.)
Filter Type
Casing
Framed
Width 0n.}
Side Return
Bottom Return
17-112
21
24-1/2
(1)16X25X11-
(1) 16X25X11-
Cteanable
(1) 16 X25X
1"
(t) 20 X 25 X 11. Cteanable
(1 or 2) 16X25X
1" (1) 24X25X
11- Cteanable
* Filters may be field modified by catting filter material and support rods (3) in
filters. Alternate sizes can be ordered from your distributor or dealer
? Factory-provided with furnace.
\
\
FILTER
FILTER
RETAINER
SUPPORT
Fig. 25--Bottom
FHter Arrangement
A00290
To remove
bottom
closure
panel,
per%tin
%llowing:
1
Tilt or raise I_urnace and remove
2 screws
iaolding
fi'ont filler
panel.
(See Fig. 26.)
2. Rotate
fi'ont filler panel
downward
to release
holding
tabs.
3. Remove
bottom
closure
panel.
4. Reinstall
front filler panel
and screws.
Step
7--Gas
Piping
Gas piping must be installed
in accordance
with national
and local
codes.
Refer to NFGC
in tiae US
Canadian
installations
must be
made
in accordance
with NSCNGPI(
and all authorities
having
jurisdiction.
Gas supply
line should
be a separate
line 1atoning
directly
fiom
meter
to t:m'nace,
if possible.
Ref)r
to Table
3 %r
recommended
gas pipe sizing.
Risers
must be used to connect
to
£umace
and to meter.
Support
all gas piping
with
appropriate
straps,
hangers,
etc. Use a minimun_
of 1 hanger
every
6 t't. Joint
compound
(pipe
dope)
should
be applied
sparingly
and only to
male threads
of joints.
Pipe dope must be resistant
to propane
gas.
19