Combustion-Air And Vent Pipe Diameter; Combustion-Air And Vent Pipe Attachment; Short Vent (5 To 8 Ft) System - Carrier 58MVP Installation, Start-Up, And Operating Instructions Manual

Series 180 4-vvay mumtipoise dkect-vent variabme-capacity condensing gas furnace
Table of Contents

Advertisement

water
&oplets.
These
droplets
may be undesirable_
and a 12oiu
mininmm
offset pipe section is recommended,
as shown
in Fig. 35,
to reduce
excessive
droplets
from exiting
vent pipe outlet.
CombustionoAir
and Vent
Pipe Diameter
Determine
combustionoair
and vent pipe diameter.
1. Using
Table
7,
individually
determine
the
smallest
combustionoair
and vent pipe
diameters.
Pick
the larger
of
these
2 pipe
diameters
and
use
this
diameter
tbr
both
combustionoair
and vent pipes.
2. When
installing
vent
systems
of short
pipe
tengd_, use the
smallest
allowable
pipe diameter.
Do not use pipe size greater
than required
or incomplete
combustion,
flame disturbance,
or
flame sense lockout
may occur.
NOTE:
Do not count
elbows
or pipe sections
in tem_inations
or
within
Nrnace.
See shaded
areas in Fig. 37, 38, 39, 40, and 41.
EXAMPLE:
An 080-14
size f:m_lace located
in Indianapolis,
elcvation
650 ft above sea level,
could be installed
in an application
requiring
3 elbows
and
17 ft of vent
pipe,
along
with
5
elbows
and 16 ft of congbustionoair
pipe. Table 6 indicates
this application
would
allow
a l-li2-in
dianreter
veut pipe,
but require
a 2Din. diameter
combustion
air pipe (loli2oin.
pipe is good fbr 20 ft with 3 elbows,
but only 10 ft with 5
elbows)
Therefbre,
2Din diameter
pipe must
be used for
both
vent and combustionoair
pipes
since
larger
required
diameter
must
always
be used
fbr both
pipes.
If same
installation
were
in Albuquerque,
elevation
5250
ft above
sea level,
installation
would
require
2-in.
vent
pipe
and
combustion-air
pipe. At 500Io
to d000oft
elevation,
1ol/2o
in. pipe is not allowed
with 5 elbows,
but 2-in. pipe is good
for 68 ft with 5 elbows.
(ombustion-Air
and Vent Pipe Attachment
NOTE:
All pipe joint._; must
be cemented
except
attachmeut
of
combustion-air
pipe to iulet
housing
connection
since
it may be
necessary
to remove
pipe for servicing.
1. Attach
combustion-air
pipe as fbllows:
VENT
:--12r'M'N
H
PIPE _1
I
_,f
COMIUSTI_-AIR
PIPE
HORIZONTAL
TO ROOF
_12"
MIN -__
VENT PIPE --_
COMBUSTION-AIR
PIPE
HORIZONTAL
TO SIDEWALL
COMBUSTION-AIR
PIPE --_
:_
12" MIN-_B--
COMBUSTION-AIR
PIPE _,
f
VENT PIPE
12" MIN
VENT PIPE
VERTICALTO
ROOF
VERTICAL TO SIDEWALL
NOTE: A 12 In. minimum offset pipe section is recommended
with
short (5 to 8 ft) vent systems. This recommendation
is to reduce
excessive condensate
droplets from exiting the vent pipe.
Fig. 3g--Short
Vent (5 to 8 Ft) System
3O
A96230