Custom
Panel
Dimensions
36" BzHlt-ln Refrigerator
Side View
not to scale
--24
3/4"--
4 _
Front View
(not to scale)
--35"
Case Width/
--36"
Overall
Width
12 1/4" max
10-3/4"
rrfin
84 1/2" max
83" min
72 1/4"
J
84 112" max
83-114" min
Finished
Opening
*Finished Width
Locate Grounded
Electrical outlet
Within Solid
Area Above
A12
3t8"-
Locate Water
Supply
Within
the Shaded
Wall View
(not to Scale)
74" From
Floor to
Bottom
of
Electrical
Area
3 1/2"
1/2"
--_-
*36" Min. for a flush installation
into an enclosure.
"35-1/2"
Min. for a semi-flush
installation
into an enclosure.
Note: Additional
cutout
width
may be required
when side panels
are
used. Add side panel thickness
to the finished
cutout
to calculate
rough-in
width.
See installation
examples
on page 4.
ZIS36N
(Non-dispenser)
Design
Information
Cutout dimensions,
clearances
and side panel sizes are
determined
by the many installation
options
available.
Side panels must be used whenever
the sides of the
refrigerator
will be exposed.
Side panels are not required
when refrigerator
is installed into an enclosure
or
between
pantry and oven cabinets.
IMPORTANT-Side
panels, 1/2" minimum thickness,
are required when using
FRAMELESS CABINETS.
• Field installed custom panels, Lexan ® or stainless steel
panels are required.
The door panels and grille panel
sizes vary to accommodate
the kit being used.
• A custom toekick can be installed to match or comple-
ment the surrounding
cabinetry.
Use the supplied
toekick as a template
to cut out notches
around hinges
and water lines.
Optional
Kits:
ZWBP36: Black Lexan ® Panel Kit (no trim kit required).
ZWWP36: White Lexan C"_' Panel Kit (no trim kit required).
ZWSP36: Stainless Steel Panel Kit (no trim kit required).
ZKHI: For installation
of a custom handle on 1/4" panels.
ZKT36: For installation
of 3/4" custom panels.
ZKHTI: For installation
of a custom
handle on 3/4"
panels. (This kit must be used in combination
with
ZKT36.)
• ZKHSSI: Tubular Stainless
Steel handles on 1/4" panels.
• ZKHTSSI: Tubular Stainless
Steel handles on 3/4"
panels. (This kit must be used in combination
with
ZKT36.)
• ZG2: 1/4" grille panel frame side pieces for 83", 83-112"
and 84-1/2" installation
heights. Factory set height is 84".
• ZWTI: White toekick (supplied toekick is black).
Includes a white toekick to fit 36, 42, 48" side-by-side
models and 36" bottom mount and single door models.
Additional
Specifications
• A 115 volt 60 Hz., 15 or 20 amp power supply is required.
An individual
properly
grounded
branch circuit
or
circuit breaker is recommended.
Install a properly
grounded
3-prong electrical
receptacle
recessed
into
the back wall. Electrical
must be located on rear wall.
• Water line can enter opening through the floor or back
wall. The water line should be 1/4" O.D. copper tubing
between
the cold water line and water connection
location,
long enough to extend to the front of the
refrigerator.
Installation
of an easily accessible
shut off
valve in the water line is recommended.
Clearances
If the refrigerator
is to be installed
in a corner:
• A 4" min. clearance
between
the case trim and
adjacent
wall on both sides of the refrigerator
will
assure a 90 ° door opening and access to all drawers.
A 10" clearance
is required on both sides for removal
of pans.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Monogram zisw36dMonogram zisb36d

Table of Contents