RETROFIT
SLEEVE
PREPARATION
IMPORTANT:
Inspect
wall
sleeve
thoroughly
prior
to
installation.
Manufacturer
does
not
assume
responsibility
for costs or damages
due to
defects
in sleeve or for improper
installation.
ELECTRICAL
SHOCK
HAZARD
Failnre
to %llow
this warning
conld resnlt
in personal
injury
or death.
Disconnect
all power
to unit to avoid possible
electrical
shock
during
installation.
GE
Plastic
Sleeve
= Remove
bottom
seal
from
plastic
sleeve.
See Fig. 6.
INSTALLATION
OF A GREE
WALL
SLEEVE
USING
A NON-GREE
GRILLE
This application
has become
more
common
due to
pre-manufactured
windows
with
built-in
grilles
or
renovations
where
a Gree
sleeve
is used
with
an
existing
non-Gree
grille.
Use of a Gree wall
sleeve
with
a non-Gree
grille
requires
installation
of an Accessory
Baffle
Kit (see
Fig. 7), which
ensures
a good seal between
the unit
and exterior
grille
to prevent
air recirculation.
Air
recirculation
is a large
contributor
to performance
loss and premature
damage
to major components.
CONDENSATE
REMOVAL
SYSTEM
Gree's
series has a new condensate
(water)
disposal
system.
The outdoor
fan prop has a built in slinger
ring which draws condensate
water and sprays it on the
warm
outdoor
coil for evaporation.
Thus providing
better
disposal
of excess
condensate
and improving
unit operating
efficiency.
It is normal
and desirable
to have some condensate
water in the base pan to boost operating
efficiency.
All
heat
pump
units
contain
a condensate
drain
valve. This temperature
activated
drain valve
opens
when
the outdoor
temperature
drops
below
55 ° F
(12.8 ° C) to prevent
water from freezing
in the base
pan. The water drains from the unit though
the wall
sleeve
and out the wall
sleeve's
rear condensate
drainage
holes.
If the condensate
drain kit accessory
is attached
to the
wall
sleeve,
water
will
drain
through
the condensate
drain tube.
NOTE:
This unit will not always
evaporate
1{)0%
of the unit
generated
condensate
and
blown
in
rain
water,
If it is necessary
to control
1!)0%
of
the condensate,
the Drain
Kit (Part
No,: DRAIN-
and
a
building
condensate
drain
system
is recommended,
BOTTOM
SEAL
Fig. 6 = Remove
Bottom
Seal From
GE Plastic
Sleeve
Fig. 7 = Accessory
Baffle
Kit
SLINGER
RING
CONDENSER
SECTION
A(17678
Condensate
Removal
System