Keypad Configuration - Gree E-TAC Installation And Operation Instructions Manual

Packaged terminal air conditioner/heat pump 7000-15000 btuh
Hide thumbs Also See for E-TAC:
Table of Contents

Advertisement

KEYPAD
CONFIGURATION
Key_pad Configuration
Allows further configuration
of system to desired
application.
Changes do not take affect until power is
cycled on the unit.
To enter KeNpad
configuration
Cycle power
to unit.
Press and hold the Fan Speed
Button
and the COOLER
button
for 5 continuous
seconds,
-within 30 seconds
of the unit being powered
up. If the unit
has had power
for more
than
30
continuous
seconds,
keypad
configuration
cannot be
entered.
When
keypad
configuration
mode
is first
entered,
it will default to Fahrenheit/Celsius
Display
Mode.
To scroll throu_zpad
Configuration
Press and release
the Fan Speed button.
The stored
value will be displayed.
To modi[_uration
settings
Press and release the Setpoint
Up or Setpoint
Down
buttons.
To exit Ke2_pad Configuration
Keypad Configuration
-will end on its own 30 seconds
after the last button press or when the MODE button
on the Keypad
is pressed.
Fahrenheit!
Celsius
Dis_y
Switch:
Change
between
degrees
Fahrenheit
and Celsius
on
the display.
An "F" indicates
Fahrenheit
display
and
'C' indicates
Celsius.
Default
is degrees
"F".
Indoor
Air Temperature
Sensor
Biasing
for
Cooling
mode:
Sometimes
known
as
an
anticipator,
the
air
temperature
sensor bias is used to adjust the room air
temperature
reading
when
in cooling
mode.
(Not
normally
required.)
Default biasing value is zero. The
range for biasing
change
is -6 deg F to +6 deg F (-3
deg C to +3 deg C)
Indoor
Air Temperature
Sensor
Biasin fg__r
Heating
mode:
Sometimes
known
as
an
anticipator,
the
air
temperature
sensor bias is used to adjust the room air
temperature
reading
when
in heating
mode.
(Not
normally
required.)
Default biasing value is zero. The
range for biasing
change
is -6 deg F to +6 deg F (-3
deg C to +3 deg C)
Indoor
Temperature
Displa_Z:
Change between
showing
setpoint
only on the display
during heating
and cooling
modes "SP" or displaying
room temperature
during heating
and cooling
modes
"AA".
"SP" mode is the default
mode.
If "SP" is selected,
only the setpoint
will be
displayed
during heating
and cooling
modes,
regardless
of what the real temperature
is in
the room.
If
"AA"
mode
is
selected,
the
room
temperature
will be displayed
during heating,
cooling
and fan only modes.
-- If the mode button has been changed
to
either heating or cooling modes, setpoint
will be displayed
for 10 seconds.
After
the 10 seconds,
the room temperature
will again be displayed.
-- If the on/off button is depressed
(when
the unit is off) and the last mode was
either
cooling
or heating
mode,
the
setpoint will be displayed
for 10 seconds
before displaying
room temperature.
--During
heating
and cooling
modes,
if
either the up or down
setpoint
key is
depressed,
the display
will
show
the
setpoint until 10 seconds after the last up
or down
key press,
Then
the room
temperature
will be displayed
again,
12