Unit Features - Gree E-TAC Installation And Operation Instructions Manual

Packaged terminal air conditioner/heat pump 7000-15000 btuh
Hide thumbs Also See for E-TAC:
Table of Contents

Advertisement

UNIT
FEATURES
Fig. 2 - E-TAC
Front
Panel
This
E-TAC
has
many
exciting
features
which
are different
than
those
found
on standard
PTAC
models.
The
owner
must
be familiar
with
these
features
in order to fully understand
the operation
and
capability
of the unit.
* Intelligence
- Your E-TAC
unit has an on board
computer
that utilizes real time diagnostics
to prolong
the life of your unit. There is an LED indicator
on the
control
board, behind
the front panel, that will flash
an error code if the unit has detected
some kind of
fault
condition.
In
many
cases,
the
unit
will
automatically
clear the fault condition
and continue
operating
with no interruption.
In some cases,
the
condition
cannot
be cleared
and the unit will require
service.
In those cases, an "Fx" failure
mode will be
displayed
on the digital display.
For a detailed
list of
all error codes
and "Fx"
conditions,
see Table
6 =
Stattts LED Indicator
D@'nitions
for further
details.
* Memory
- Your E-TAC
unit also has memory.
If
power
is lost,
all of the control
settings
(setpoint,
mode,
fan
speed,
on/off
and
configuration)
are
remembered.
So when power is restored,
the unit -will
start back up in the mode (and configuration)
it was
in, when power
was lost.
* Premium
Sound - Your Premium
E-TAC is also the
quietest
PTAC
ever.
Not only
does
it have
2 fan
motors
and a tangential
blower
wheel
for optimum
sound, the indoor fan will always run a minimum
of 10
seconds
before
the compressor,
to help reduce
any
compressor
starting noise.
* Random
Compressor
restart
= To help prevent
power
surges
after
a power
outage
(from
many
of
your
E=TACs
starting
at
the
same
time),
the
compressor
is equipped
with a 2:45 to 3:15 random
restart delay feature.
Whenever
the unit is plugged
in,
or power
has been restarted,
a random
compressor
restart will occur.
* Dry Mode
- will help to manage
and reduce
the
humidity
in the room, making it more comfortable.
In
DRY mode,
the unit will modulate
cooling
mode at
low fan speed until the room temperature
is 4 deg. F
below the room temperature
setting regardless
of fan
mode selection.
Dry mode should not be considered
a
substitute
for a stand alone dehumidifier.
* Compressor
Protection
= To prevent
short cycling
of the compressor
and maximize
it's life, there is a
random
start=up
delay
of
3
minutes
on
the
compressor
and a minimum
compressor
run time of 3
minutes.
* Automatic
room freeze protection
- automatically
will keep the temperature
in the room from getting
too cold, -where water pipes might freeze.
If the unit
is configured
for the freeze protection
feature
to be
active (which is the default condition),
then-whenever
power
is supplied
to the unit,
if the unit
senses
temperature
below 40°F (4.4°C),
the fan motor
and
electric
heater are turned
on and -will warm the room
to 50 ° F (10°C).
If Freeze protection
is not required,
change
the configuration
switch to turn the feature off
(see section
on unit configuration).
° Automatic
defrost
protection
(for
heat
pump
models
only)
- When
the outdoor
temperature
gets
too cold (approx.
40°F / 4.4°C)
and the unit can no
longer effectively
heat with the compressor,
the unit
will automatically
switch to electric heating.
The unit
will
then heat with
electric
heat until
the outside
temperature
rises enough
(approx.
40°F / 4.4°C),
so
the compressor
can be used again.
* Automatic
Quick
Warm-up
(for
heat
pump
models
only)
= If the room temperature
falls to 5°F
(2.8°C) below
the set point temperature,
the reverse
cycle heat is shut off and the electric
strip heat is
turned on for one cycle, until heating
is satisfied.
* LED Indicator's
and Buttons
= The touch pad has
buttons
for
MODE,
FAN SPEED,
ON/OFF,
SETPOINT
UP and SETPOINT
DOWN.
It also has
LEDs that correspond
to the mode,
fan speed
and
setpoint
operation,
to indicate
the unit's
status. The
LEDs
below
the mode
button,
FAN,
COOL,
and
HEAT,
indicate
what operating
mode is active.
The
LEDs
below
the Fan button,
Low,
Med
and Hi,
indicate
the fan speed
that
is selected.
The LED
located
in the lower
right corner
is the unit On/Off
status LED. if the unit is in ON mode, the LED will
be green,
if the unit is OFF, the LED will be red.
* Configure
Fan to Optimize
Selected
Application
-
Unit
can
be optimized
to selected
application
by
configuring
the fan to run in continuous
mode or cycle
on and off with the compressor
and electric heater (can
be different
for both heating
and cooling
modes).
In
cycle mode, fan will continue
to run 60 seconds
after
compressor
or electric
heater stops in order blow off
any residual
heat or cool left on coil.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Etac seriesGb series

Table of Contents