ELECTRICAL
DATA
ELECTRICAL
SHOCK
HAZARD
Failure
to follow
this warning
could result
in personal
injury or death and/or property
damage
DO NOT alter cord or plug or use an extension
cord.
IMPORTANT:
For
265V
units,
if power
cord
accessory option is selected, the cord is only 18 inches
long and
must
plug
into the accessory
electrical
265V subbase.
Be sure that your outlet matches
the appropriate
blade
configuration
of the plug and that it is within reach of
the service
cord.
All wiring,
including
installation
of the receptacle,
must be in accordance
with the NEC and local codes,
ordinances
and regulations.
National
codes
require
the use of an arc fault or leakage
current
detection
device on all 208/230V
power cords. Be sure to select
the correct
cord for your installation.
ALL
UNITS
Wire Size
Use recommended
wire
size given
in Table
1 and
install
a single
branch
circuit.
All
wiring
must
comply
with local and national
codes. All units
are
designed
to operate
offONE
single branch
circuits
only.
NOTE:
Use copper conductors
only.
Table
1--SUGGESTED
BRANCH
CIRCUIT
WIRE SIZES*
NAMEPLATE AMPS
7.0 to 12
12.1 to 16
16.1 to 24
LEGEND
AWG - American
Wire Gauge
* Single circuit from main box.
1- Based on copper
wire at 60°C temperature
rating.
AWG WIRE SIZEt
14
12
10
Groundin_
For
safety
and
protection,
the unit
is grounded
through
the service
cord plug or through
separate
ground
wire provided
on hard wired
units.
Be sure
that the branch
circuit
or general
purpose
outlet
is
grounded.
VOLTAGE
SUPPLY
Check
voltage
supply
at outlet.
For
satisfactory
results,
the voltage
range must always be within
the
ranges
found on the data information
plate.
Cord-connected
Units
The 208/230-v field supplied outlet must match the plug
for the standard
208/230-v
units and be within reach
of the service
cord.
The standard
cord-connected
265-v
units require
an accessory
electrical
subbase
for operation.
Refer to Table 2 for proper receptacle
and fuse type.
Power
Cord Protection
The power
cord for 208/230v
units
provide
power
cord
fire
protection.
Unit
power
automatically
disconnects
when
unsafe
conditions
are detected.
Power to the unit can be restored
by pressing
the reset
button
on plug head.
Upon
completion
of unit installation
for 208/230V
models,
an operational
check
should
be performed
using
the TEST/RESET
buttons
on the plug head.
NOTE:
The
265v
models
do not incorporate
this
feature
as they require
use of the electrical
subbase
accessory.
Table 2--RECEPTACLES
AND FUSE
TYPES
- 250,265
VOLTS
RECEPTACLE
AMPS
15
20
30
15
20
30
RATED VOLTS
250
250
250
265
265
265
TIME-
DELAY TYPE FUSE (or
15
20*
30
15
20
30
HACR Circuit
Breaker)
LEGEND
HACR
- Heating, Air Conditioning,
Refrigeration
*
May be used for 15-amp
applications
if fused for 15 amps.