Wall Thermostat Terminal; Energy Management Input; Intelligent Self-Checking Control - Gree E-TAC Installation And Operation Instructions Manual

Packaged terminal air conditioner/heat pump 7000-15000 btuh
Hide thumbs Also See for E-TAC:
Table of Contents

Advertisement

TERMINAL
CONNECTIONS
The wall thermostat
terminal
block is located behind
the front panel and is easily accessible
on front of control
panel.
STATUS
LED
/
/
Mana2eme
mg
Wall Themlostat
Energy
Temfinal
Connections
Tmminal
Connections
Fig. 24 - Terminal
Connector
and
Status
LED Location
UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment
damage or improper operation,
Improper wiring may damage unit electronics. Common
busing is not permitted, Damage or erratic operation may
result,
Energy
--
Management
(24VAC
in)
(_
--
Common
©w
©¥
O
See
Note
1
©
G.
©
G,
C
See
Note
2
TERMINAL
BLOCK
NOTES:
1. Use terminal
"O" for heat pump connection
only.
2. Terminal "C" (common)
is typically
only required for digital
thermostats.
TERMINAL
DESIGNATION
R
24 VAC
W
Electric Heat
Y
Compressor
O
Reversing Valve
GH
High Fan
GL
Low Fan
C
Common
NOTE: Any illegal input combinations
will be captured
as thermostat
wiring
failures and will light the STATUS LED indicator on main board
(see Intelligent
Self-Checking
Control section)
Fig.
25 - Wiring
Connections
ENERGY
MANAGEMENT
INPUT
(FRONT
DESK
CONTROL)
The controller
can handle a switch signal from remote energy management
input, called EM signal or front desk
control.
Input must be 24VAC. If system receives
a 24VAC signal, it will turn unit off; otherwise,
the unit runs in
normal
control.
This
function
will be disabled
under
Freeze
Guard
protection.
See Fig.
25 for terminal
connections.
INTELLIGENT
SELF-CHECKING
CONTROL
Your E-TAC has a computer
board
that continuously
checks
key components
of the unit to ensure
they are
operating
properly.
Under normal operation,
unit status indicator
(STATUS,
on main PCB), light is steadily ON.
If there is a major problem,
the unit will shut down and display a diagnostic
failure code on the unit's
display.
If
it is only a minor failure and unit is correcting
the fault by itself, the diagnostic
code will be flashed on the status
LED that can easily be seen when the front panel is removed
(see Fig. 24). Failure
STATUS
codes are defined
in the table below
Table 6
STATUS LED Indicator Definitions
l
Indoor
air temp sensor open/short
8-s%m'nent display
'FI ', with
STATUS
light flash
1 times and off 3 sec, repeat
2
Indoor coil sensor open or short
8-s%mnent display 'F2', with STATUS light flash 2 times and off 3 sec, repeat
3
Outdoor coil sensor open/short
8-s%mnent display 'F4', with STATUS light flash 3 times and off 3 sec, repeat
4
Freeze Guard protection
8-s%mnent display 'FP'
5
Indoor coil freeze protection
STATU light flash 5 times and off"3 see, repeat
6
Outdoor coil high temp protection
STATU light flash 6 times and off 3 sec, repeat
7
Defrost (heat pump type)
STATU light flash 7 times and off 3 sec, repeat
8
Indoor coil high temp protection
STATU light flash 8 times and off 3 sec, repeat
9
Thermostat wiring error
STATU light flash 9 times and off 3 see, repeat
tO
High pressure protection (optional)
8-s%mnent display 'El ', (the highest display grade)
NOTE:
When stares light is flashing, it will be ON for 1 seconds and OFF tbr another 1 seconds.
14