OPERATION
IMPORTANT:
When
unit is first
started_
high
humidity
conditions
can cause
condensation
to form
on
discharge
grille,
Keep
doors
and
windows
closed.
Room
humidity
will decrease
and
moisture
will
evaporate,
TEMP CONTROL
FAN, MODE& OPERATION
Fig. 26 - E-TAC
CONTROLS
ABOUT THE CONTROLS
ON YOUR UNIT
NOTE:
In case of a power
failure,
the unit
will
remember
the last programmed
settings
and
will
restart
to those settings.
1. ON and OFF MODES
ON MODE
- Places unit in ready or operation
mode.
OFF MODE
- Places unit in standby mode.
NOTE:
The LED above
the ON/OFF
button
will be
green when unit is ON and red when the unit is OFF.
All other
LEDs will be off when
unit is set to OFF
mode.
NOTE:
Prover remains
connected
to unit.
2. TEMP
CONTROL
Temp Control
is used to maintain
room temperature.
Compressor
will cycle on and offto keep room at the
requested
level of comfort.
COOLER
- Lowers
temperature.
(Minimum
temperature
setting is 61 ° F/16 ° C)
WARMER
- Raises temperature.
(Maximum
temperature
setting
is 86 ° F/30 ° C)
3. OPERATING
MODE
MODE-COOL
- For cooling
MODE-DRY
- For cooling
with addition
moisture
removal.
MODE-HEAT
- For heating
MODE-FAN
- For fan-only
operation
NOTE:
If unit is a heat pump, raising the heat setting
5°F (2.8°C) will cause unit to use its electric
heating
elements
for one cycle
in order
to reach
the new
requested
temperature
quickly.
4. FAN SPEED
Set fan operation for HI, MED, LO and AUTO speed.
AUTO FAN MODE
- Adjust the indoor fan speed to
balance
room comfort
and quietness.
The fan speed
will increase
the farther away from the selected
room
temperature
to quickly reach desired room temperature.
As
the
room
temperature
approaches
the
selected
temperature,
the indoor
fan slows
down
to a quiet
comfort
level.
5. TIMER
MODE
Timer
ON:
When
the unit is ON, the Timer
ON
function
can be set. Time setting
range is 0.5 to 24
hours. When the selected time is reached,
the unit will
turn ON and operate according
to system settings.
Timer
OFF:
When the unit is OFK the Timer
OFF
function
can be set. Time setting
range is 0.5 to 24
hours. When the selected time is reached,
the unit will
turn OFE
Timer
Setting:
Press
Timer
button
to set timer
function.
The Timer LED will turn ON and "88" will
be displayed.
Press the up or down arrows to select the
desired
time.
15