3.3 Gas Connections (cont.)
G. Only qualified service personnel should make adjustments to the regulators.
H. Orifices: The fryer can be configured to operate on any available gas. The correct safety
control valve, appropriate gas orifices, and pilot burner are installed at the factory. While the
valve can be adjusted in the field, only qualified service personnel should make any
adjustments with the proper test equipment.
If gas odors are detected, the gas supply must be shut off at the main shut-off valve.
The local gas company or FASC should be contacted immediately to rectify the
I.
After connecting the fryer to the gas supply, bleed the gas line of air to ensure that the pilot
will ignite quickly.
TRIATHLON SERIES GAS FRYERS
CHAPTER 3: INSTALLATION
WARNING
problem.
3-4