NEC N8800-096F User Manual page 336

Express5800 series
Hide thumbs Also See for N8800-096F:
Table of Contents

Advertisement

On-screen error message
9039 Not keep last boot
order
9070 The error occurred
during water-cooling
unit sensor reading
NOTICE System is force
boot with POST
error
9000
9007
9008
9010 - 9015
9020
9022 - 9023
9024
Cause
Unintended operations such
as incorrect DC off are
performed.
The sensor of water-cooling
kit is faulty.
Abnormality of one or both
sides of modules is detected.
A serious error occurred
during a POST.
Forced power off occurred by
another CPU/IO module has
a problem.
Forced power off occurred by
another CPU/IO module has
a problem.
Can not boot from target Disk.
CPU is faulty.
Initialization of the cross-link
between the CPU/IO
modules and access are
faulty.
Disconnect the cross-link
between the CPU/IO
modules.
Troubleshooting 7-9
Action
Reconfigure the boot option by
using the BIOS setup. If
reconfiguring the boot option
does not help, replace the
CPU/IO module.
Replace the water-cooling kit. If
turning on/off AC does not help,
replace CPU/IO module or ft
Remote Management Card.
View other error information and
the error information of standby
CPU/IO module.
There are some error messages
in addition to this error code.
Check the other error message.
Pull out another CPU/IO module
and install it.
If this does not help, replace the
CPU/IO module.
Pull out another CPU/IO module
and install it.
If this does not help, replace the
CPU/IO module.
Check the target disk.
In addition, replace it if required.
If this does not help, replace the
CPU/IO module.
Replace the CPU.
If this does not help, replace the
CPU/IO module.
When the system is running in
the duplex mode, it is no
problem.
If the system cannot be running
in the duplex mode due to
continuous this error, replace the
CPU/IO module.
If this does not help, replace
another CPU/IO module or
center plane.
When the system is running in
the duplex mode, it is no
problem.
If the system cannot be running
in the duplex mode due to
continuous this error, replace the
CPU/IO module.
If this does not help, replace
another CPU/IO module or
center plane.

Advertisement