On-screen error message
0251 System CMOS
checksum bad-Default
configuration used
0252 Password checksum
bad -Password cleared
0260 System Timer error
0270 Real time clock error
0271 Check date and time
setting
02D0 System cache error -
Cache disabled
02D1 System Memory
exceeds the CPU's
caching limit
0613 COM A configuration
change
0614 COM A config, error -
device disable
0B28 Unsupported
Processor detected on
Processor 1
0B29 Unsupported
Processor detected on
Processor 2
0B60 DIMM group #1 has
been disabled
0B61 DIMM group #2 has
been disabled
0B62 DIMM group #3 has
been disabled
0B70 The error occurred
during temperature
sensor reading
0B71 System Temperature
out of the range
0B74 The error occurred
during voltage sensor
reading
0B75 System voltage out of
the range
0B80 BMC Memory Test
Failed
0B81 BMC Firmware Code
Area CRC check failed
0B82 BMC core Hardware
failure
Cause
System CMOS configuration
is changed.
Password is cleared.
System Timer is faulty.
RTC is faulty.
Date and time are incorrectly
set.
CPU cache is faulty.
CPU cache is faulty.
COM A configuration is faulty.
Device constructing COM A is
faulty.
Unsupported CPU is mounted.
Unsupported CPU is mounted.
DIMM is faulty.
I2C pass is faulty.
Sensor is faulty.
Temperature is abnormal.
Fan is abnormal.
I2C pass is faulty.
Sensor is faulty.
Voltage is abnormal.
RMC device is faulty.
Troubleshooting 7-5
Action
Reconfigure the system CMOS
by using BIOS setup.
Clear system CMOS using
hardware jumper.
Reconfigure by using BIOS
setup.
Clear system CMOS using
hardware jumper.
Reconfigure by using BIOS setup.
If replacing the CPU does not
help, replace the CPU/IO module.
If restarting does not help after
resetting the setting to default by
using BIOS setup, replace the
CPU/IO module.
Check the supported CPU and
replace it. If this does not help,
replace the CPU/IO module.
Replace DIMM Group#1.
Replace DIMM Group#2.
Replace DIMM Group#3.
Replace the part that relevant
sensor is mounted.
Check if fan is faulty or clogging
has occurred. If there is no
problem, replace CPU/IO module.
Replace the part that relevant
sensor is mounted.
If turning AC power off and on
does not help, replace the
CPU/IO module.
Replace the CPU/IO module or ft
Remote Management Card
(option).