Setup Window - NEC N8800-096F User Manual

Express5800 series
Hide thumbs Also See for N8800-096F:
Table of Contents

Advertisement

On the other hand, if the BIOS version of the running CPU/IO module is older than the one of
the module to be installed later, after installing the module and making the system duplexed,
the firmware is updated by temporarily stopping the running module and starting it again.
While using this function, the module is switched automatically, and the [GeminiEngine
Monitor Tool] window is displayed. Wait until the window closes automatically without
performing operations such as starting, stopping and diagnosing modules. Set whether to
enable this function on the setup window described later. Also, if updating the firmware stops
without completion, check the system status with Server Maintenance Utility or event log, and
start the module that has been stopped.

Setup Window

GeminiEngine Monitor Tool can be set on the following setup window:
From the Start menu, select [All Programs], [GeminiEngine Monitor Tool] and then
[Configuration].
If you start the configuration function, the following [GeminiEngine Monitor Tool Configuration]
window is displayed. Below explains the check boxes and actions to be taken when they are
selected:
Action for detecting failed redundant: You can set actions for when the status changes from
duplex to simplex
Beep: If the server status changes from duplex to simplex, the tool sounds beeps at a fixed
interval.
Warning message: If the server status changes from duplex to simplex, a warning message is
displayed.
Installing and Using Utilities 5-87

Advertisement

Table of Contents
loading

Table of Contents