FEATURES & OPERATING CONTROLS (continued)
VENTILATOR SECTION
ITEM
DESCRIPTION
1
NAMEPLATE
FIRE SUPPRESSION AGENT
a6.
TANK (1.5 gal.)
8
ADJUSTABLE (FRONT) LEG
9
RIGID (REAR) CASTER
a10.
MANUAL PULL STATION
a11.
FUSIBLE LINKS
12
LOWER REAR ACCESS PANEL
a15.
DISCHARGE NOZZLE
16
GREASE BAFFLE
18
PRE-FILTER ASSEMBLY
19
HEPA/CHARCOAL FILTER PACK
22
GREASE CUP
23
GREASE TROUGH
28
VENTILATOR EXHAUST DUCT
a31.
STATUS INDICATOR
38
POWER CORD
40
FUSES
41
POWER CONTACTOR
42
BUILDING FIRE ALARM RELAY
43
GROUND LUG
44
INTERLOCK TERMINAL
53
FILTER INTERLOCK SWITCHES
56
VENTILATOR FAN
57
HOOD SIDE SHIELD
58
SIDE SPACERS
Features & Operating Controls
Gives manufacturer, make and model description. Also lists voltage and
amperage data.
Container for Ansulex™ Low-pH liquid fire suppression liquid.
Allows the unit to be leveled.
Allows the unit to be easily positioned by lifting the front of the unit slightly.
Provides a means of manual activation of the fire suppression system.
PULL ONLY IN CASE OF FIRE!
Automatically activates fire suppression system in the event of fire on the
cooktop.
Allows access to Ansul® fire suppression agent tank (a6) and controls also
access to main power contactor (41).
Fire suppression media discharges here (2 places).
Extracts and drains most grease and moisture from the air flow.
Comprises the PRE-FILTER FRAME and a replaceable PRE-FILTER.
Stops larger particles of grease from reaching the FILTER PACK for
reduced maintenance costs.
Stops most grease and smoke particles. Also assists in some cooking
odor removal.
Collects grease/moisture drained from grease trough (23).
Directs grease/moisture removed by grease baffle to grease cup.
Exit point for ventilator airflow - on top left rear of unit. DO NOT
BLOCK
Displays status of fire suppression system (COCKED - FIRED) If FIRED, a
buzzer will sound continuously.
6' cord and cap. Plug for NEMA 15-60R (receptacle by user).
Provide over-current protection.
Energizes cooking appliances only while ventilator section is sensed as
operational.
Reports fire alarm condition to building fire management system.
Ground wire of power cord connects here.
Provides connection for shut-down control by building fire management
system.
Proper installation of grease baffle and filter pack close these switches in
ventilator sensor circuit.
Provides air movement for ventilation.
Required on left and right sides of hood. Factory installed.
Required to maintain 6" spacing from combustibles. Field installed.
3