ID
Event Text
PoE
0800B
Overvoltage
protection is
activated
Antenna
0800D
Overvoltage
protection is
activated
Undervoltage
08010
has been
detected
Lost
0801B
connection to
the GPS
receiver
Uploading
0801D
firmware to
antenna
Chapter 5: Troubleshooting
Explanation
Overvoltage is
detected in the
terminal. The
terminal will be
shut down in 10
minutes.
Overvoltage is
detected in the
antenna. The
terminal will be
shut down in 10
minutes.
The input voltage
has dropped below
an acceptable level.
The terminal will be
shut down in 10
seconds if the
situation persists.
Communication
with the GPS
receiver in the
antenna is lost.
New firmware is
being uploaded to
the antenna.
The Event will be
cleared when
upload has finished.
Status signaling
Remedy
Do not use the
terminal.
Contact your
distributor.
Do not use the
terminal.
Contact your
distributor.
Ensure a stable
power supply to the
terminal.
Contact your
distributor if the
warning persists.
Contact your
distributor if the
Event is not cleared
within 5 minutes.