Additional Clearances - Takagi Mobius Water Heater T-M32 ASME Installation Manual And Owner's Manual

On-demand water heater
Hide thumbs Also See for Mobius Water Heater T-M32 ASME:
Table of Contents

Advertisement

Please follow all local and national codes in regards to proper termination clearances. In the absence of
such codes, the following clearances can be used as guidelines. Local codes supersede these
guidelines.
For sidewall terminations
1ft.
1ft.
Exhaust termination
For direct-vent sidewall terminations that
use two separate penetrations for the
intake and exhaust, distance the intake
and exhaust terminations at least 3 ft.
away from each other, no matter the
orientation.
2ft.
Exhaust
termination
Exhaust and/or direct-vent
sidewall terminations should
be at least 2 ft. away from an
opposite surface/wall. Do not
place the termination directly
in front of an opening into a
building.

ADDITIONAL CLEARANCES

2ft.
Inside
corner
For multiple sidewall exhaust
terminations (e.g. multi-unit
systems), an exhaust termination
must be at least 1 ft. away from
another exhaust termination. An
exhaust termination must also be
at least 2 ft. away from an inside
corner (if the adjacent wall is less
than 2 ft. of length, the minimum
required distance away from the
inside corner will be equal to the
length of the wall).
For rooftop terminations
A: in accordance with local codes
For multiple-unit rooftop terminations (whether for standard indoor or direct-
vent installations) space all exhaust and intake terminations in accordance
with local codes. An exhaust termination must be spaced from a wall or
surface in accordance with local codes as well. In the absence of such a
code, an exhaust termination must be a horizontal distance of at least 2 ft.
away from a wall or surface.
3ft.
3ft.
3ft.
Air supply inlet
A
A
A
Air intake
Exhaust termination
- 44 -
2ft.
1ft.
1ft.
Inside
corner
Direct vent termination
For multiple-unit, direct-vent
sidewall terminations that
combine the intake and exhaust
into a single penetration, space
each direct-vent termination at
least 1 ft. away from each other,
no matter the orientation. A
direct-vent termination must also
be at least 2 ft. away from an
inside corner (if the adjacent wall
is less than 2 ft. of length, the
minimum required distance away
2ft.
A
Air intake
Exhaust
termination
A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mobius water heater t-m32

Table of Contents